CVE-2019-18341
—CVSS 3.1
5.3 medium
EPSS
2%p75
Published
()
Modified
Description
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Vendors
- siemens
- Products
- sinvr 3 central control server, sinvr 3 video server
- Weakness
- CWE-287
- Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N