CVE-2022-32748
—CVSS 3.1
8.3 high
EPSS
<1%p4
Published
()
Modified
Description
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
- Vendors
- schneider-electric
- Products
- ecostruxure cybersecurity admin expert
- Weakness
- CWE-295
- Vector
- CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
In the news0 stories
No ingested article mentions this CVE yet.