Vulnerabilities
6 CVEs · NVD, GitHub Advisories, CISA KEV, FIRST EPSS, GitHub PoC repos
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2023-47262 | The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal se The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit. NVD description · AI analysis pending | 5.2 | <1% |
| — | ||
| CVE-2020-8997 | Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and FreeStyle Libre 2 outside the U.S (announced in October 2018). NVD description · AI analysis pending | 8.8 | <1% |
| — | ||
| CVE-2017-12712 | The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be c The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. NVD description · AI analysis pending | 8.8 group max | 1% |
| — | ||
| CVE-2017-5149 | An issue was discovered in St. An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the transmitter and St. Jude Medical's web site, Merlin.net, are not verified. This may allow a man-in-the-middle attacker to access or influence communications between the identified endpoints. NVD description · AI analysis pending | 8.9 | 1% |
| — |