Vulnerabilities
44 CVEs · NVD, GitHub Advisories, CISA KEV, FIRST EPSS, GitHub PoC repos
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2023-31176 | An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session t An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details. NVD description · AI analysis pending | 9.8 group max | <1% |
| — | ||
| CVE-2023-2264 | An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to c An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to click on a link that could allow undesired behavior. See product Instruction Manual Appendix A dated 20230830 for more details. NVD description · AI analysis pending | 7.8 group max | <1% |
| — | ||
| CVE-2023-31175 | An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. NVD description · AI analysis pending | 9.8 group max | <1% |
| — | ||
| CVE-2023-34391 | Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000. NVD description · AI analysis pending | 5.5 | <1% |
| — | ||
| CVE-2023-31172 | An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attac An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. NVD description · AI analysis pending | 7.4 group max | <1% |
| — | ||
| CVE-2023-31167 | Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Scr Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778. NVD description · AI analysis pending | 8.1 | <1% |
| — | ||
| CVE-2023-31149 | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a rem An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. NVD description · AI analysis pending | 8.8 group max | 1% |
| — | ||
| CVE-2023-31161 | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an au An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service Bulletin dated 2022-11-15 for more details. NVD description · AI analysis pending | 8.8 | <1% |
| — | ||
| CVE-2018-10600 +1 in the same advisory: …10608 | SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitr SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks. NVD description · AI analysis pending | 9.8 group max | 2% |
| — | ||
| CVE-2018-10604 | SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution. NVD description · AI analysis pending | 8.8 | 2% |
| — | ||
| CVE-2017-7928 | An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R20 An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. NVD description · AI analysis pending | 10.0 | 2% |
| — |