ZeroHour
The Hacker Newspublished ()ingested @TheHackersNews

CISA Warns of Flaws Affecting Industrial Control Systems from Major Manufacturers

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2022-45444
+3 in the same advisory: …41989 …43483 …47911
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the applicatio

Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.

NVD description · AI analysis pending
9.8
group max
<1%
  • sewio real-time location system studio
CVE-2022-46823
A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 = V3.3.0 = V3.3.0 < V3.3.8).

A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 = V3.3.0 = V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.

NVD description · AI analysis pending
6.1<1%
  • mendix saml
CVE-2023-0052
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without cred

SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.

NVD description · AI analysis pending
8.8<1%
  • sauter-controls nova 220 eyk220f001 firmware
  • sauter-controls nova 230 eyk230f001 firmware
  • sauter-controls nova 106 eyk300f001 firmware
  • +1 more
CVE-2023-0053
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device

SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior have only FTP and Telnet available for device management. Any sensitive information communicated through these protocols, such as credentials, is sent in cleartext. An attacker could obtain sensitive information such as user credentials to gain access to the system.

NVD description · AI analysis pending
7.5<1%
  • sauter-controls nova 220 eyk220f001 firmware
  • sauter-controls nova 230 eyk230f001 firmware
  • sauter-controls nova 106 eyk300f001 firmware
  • +1 more
CVE-2023-22600
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284:

InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284: Improper Access Control. They allow unauthenticated devices to subscribe to MQTT topics on the same network as the device manager. An unauthorized user who knows of an existing topic name could send and receive messages to and from that topic. This includes the ability to send GET/SET configuration commands, reboot commands, and push firmware updates.

NVD description · AI analysis pending
8.1<1%
  • inhandnetworks inrouter302 firmware
  • inhandnetworks inrouter615-s firmware
Full article400 words · extracted from thehackernews.com · click to collapse

Ravie LakshmananJan 16, 2023Industrial Control Systems

The U.S. Cybersecurity and Infrastructure Security Agency (CISA) has released several Industrial Control Systems (ICS) advisories warning of critical security flaws affecting products from Sewio, InHand Networks, Sauter Controls, and Siemens.

The most severe of the flaws relate to Sewio's RTLS Studio, which could be exploited by an attacker to "obtain unauthorized access to the server, alter information, create a denial-of-service condition, gain escalated privileges, and execute arbitrary code," according to CISA.

This includes CVE-2022-45444 (CVSS score: 10.0), a case of hard-coded passwords for select users in the application's database that potentially grant remote adversaries unrestricted access.

Also notable are two command injection flaws (CVE-2022-47911 and CVE-2022-43483, CVSS scores: 9.1) and an out-of-bounds write vulnerability (CVE-2022-41989, CVSS score: 9.1) that could result in denial-of-service condition or code execution.

The vulnerabilities impact RTLS Studio version 2.0.0 up to and including version 2.6.2. Users are recommended to update to version 3.0.0 or later.

CISA, in a second alert, highlighted a set of five security defects in InHand Networks InRouter 302 and InRouter 615, including CVE-2023-22600 (CVSS score: 10.0), that could lead to command injection, information disclosure, and code execution.

"If properly chained, these vulnerabilities could result in an unauthorized remote user fully compromising every cloud-managed InHand Networks device reachable by the cloud," the agency said.

All firmware versions of InRouter 302 prior to IR302 V3.5.56 and InRouter 615 before InRouter6XX-S-V2.3.0.r5542 are susceptible to the bugs.

Security vulnerabilities have also been disclosed in Sauter Controls Nova 220, Nova 230, Nova 106, and moduNet300 that could allow unauthorized visibility to sensitive information (CVE-2023-0053, CVSS score: 7.5) and remote code execution (CVE-2023-0052, CVSS score: 9.8).

The Swiss-based automation company, however, does not plan to release fixes for the identified issues owing to the fact that the product line is no longer supported.

Lastly, the security agency detailed a cross-site scripting (XSS) flaw in Siemens Mendix SAML equipment (CVE-2022-46823, CVSS score: 9.3) that could permit a threat actor to gain sensitive information by tricking users into clicking a specially crafted link.

Users are advised to enable multi-factor authentication and update Mendix SAML to versions 2.3.4 (Mendix 8), 3.3.8 (Mendix 9, Upgrade Track), or 3.3.9 (Mendix 9, New Track) to mitigate potential risks.

Found this article interesting? Follow us on Google News, Twitter and LinkedIn to read more exclusive content we post.

Text extracted automatically; images, tables and formatting may be missing. Original: https://thehackernews.com/2023/01/cisa-warns-for-flaws-affecting.html