Researchers discovered several flaws that expose electrical substations to hack

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2018-4838
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04)

A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.

NVD description · AI analysis pending
7.51%
  • siemens en100 ethernet module iec 104 firmware
  • siemens en100 ethernet module dnp3 firmware
  • siemens en100 ethernet module modbus tcp firmware
  • +1 more
CVE-2018-4840
+1 in the same advisory: …4839
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 1

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.

NVD description · AI analysis pending
7.5
group max
2%
  • siemens siprotec compact 7sj80 firmware
  • siemens siprotec compact 7sk80 firmware
  • siemens siprotec 4 7sj66 firmware
  • +1 more
Full article487 words · extracted from securityaffairs.com · click to collapse

The ICS-CERT and Siemens published are warning organizations of security flaws in Siemens devices (SIPROTEC 4, SIPROTEC Compact, and Reyrolle devices) that could be exploited by hackers to target electrical substations.

“Successful exploitation of these vulnerabilities could allow an attacker to upload a modified device configuration that could overwrite access authorization passwords, or allow an attacker to capture certain network traffic that could contain authorization passwords.” reads the advisory published by the ICS-CERT.

The Siemens devices provide integrated protection, control, measurement, and automation functions for several applications, including electrical substations.

Siemens has already issued security patches and mitigations for the flaws.

The vulnerabilities were discovered by security experts at Positive Technologies, let’s analyzed the flaws discovered by the experts.

“Positive Technologies experts Ilya Karpov, Dmitry Sklyarov, and Alexey Stennikov detected high-risk vulnerabilities in power-system protection from Siemens that is used to control and protect such power supply facilities equipment as electrical substations or hydroelectric power stations. Siemens has fixed the vulnerabilities and issued the corresponding advisories.” states the post published by Positive Technologies.

“By exploiting these vulnerabilities, an attacker is able to change the configuration of power-system protection relay which can lead to disruption of the power equipment protection function (and potentially to an accident) or customer curtailment.”

The most severe vulnerability (rated high severity), tracked as CVE-2018-4840 can be exploited by a remote and unauthenticated attacker to modify the device’s configuration and overwrite access passwords.

“The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords. ” reads the security advisory published by Siemens.

The second flaw, tracked as CVE-2018-4839, is a medium severity issue that could be exploited by a local or network attacker to recover the access authorization password by intercepting network traffic or obtaining data from the targeted device. Once the attacker has obtained the password he can use it to gain complete access to a device.

Both CVE-2018-4840 and CVE-2018-4839 affects the EN100 Ethernet modules and the DIGSI 4 operation and configuration software used by SIPROTEC 4 and SIPROTEC Compact relay families.

Researchers at Positive Technologies also discovered a high severity vulnerability tracked as CVE-2018-4838 that resides in the web interface of the relays (SIPROTEC 4, SIPROTEC Compact, and Reyrolle relays that use EN100 modules.) that could be exploited by an unauthenticated attacker to downgrade the firmware on a device to a version that is known to be affected by vulnerabilities.

CVE-2018-4838 allows an intruder to remotely upload an obsolete firmware version that contains known vulnerabilities and to execute code on the target system. Devices that use the EN100 communication module (SIPROTEC 4, SIPROTEC Compact, and Reyrolle) can be attacked.” states the advisory published by the company.

The above issued represent a serious threat to electrical substations that are a key component in the electric grids.

[adrotate banner=”9″] [adrotate banner=”12″]

Pierluigi Paganini

(Security Affairs – electrical substations, hacking)