Siemens addressed several DoS flaws in many products
Vulnerabilities mentionedAll →
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2017-12741 | Specially crafted packets sent to port 161/udp could cause a denial of service condition. Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. NVD description · AI analysis pending | 8.7 | 3% |
| — | ||
| CVE-2019-6568 | The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. NVD description · AI analysis pending | 7.5 | 1% |
| — | ||
| CVE-2019-6575 | A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions = V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. NVD description · AI analysis pending | 7.5 | 2% |
| — |
Full article302 words · extracted from securityaffairs.com · click to collapse

Siemens Patch Tuesday updates for April 2019 address several serious vulnerabilities, including some DoS flaws in many industrial products.
Siemens has released Patch Tuesday updates that address several serious flaws including some DoS vulnerabilities. Siemens published six new advisories that cover a total of 11 vulnerabilities.
One of the issues addressed by Siemens is a high-severity DoS vulnerability (CVE-2019-6575) that affects some the SIMATIC, SINEC-NMS, SINEMA, SINUMERIK and TeleControl products.

The CVE-2019-6575 vulnerability can be exploited by a remote, unauthenticated attacker to cause a DoS condition in OPC communications component or crash a device by sending it specially crafted network packets on TCP port 4840.
“A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device.” reads the security advisory published by Siemens.
Siemens also fixed another DoS flaw tracked as CVE-2019-6568 that resides in the web server component used by many CP, SIMATIC, SINAMICS, SITOP and TIM industrial products. An unauthenticated attacker could trigger the vulnerability once obtained the network access.
The company also addressed a high-severity DoS vulnerability (CVE-2017-12741) in SIMOCODE pro V EIP that can be exploited remotely by sending specially crafted packets to the targeted application on UDP port 161.
“SIMOCODE pro V EIP is affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP).” reads the advisory published by the company.
Siemens also published security advisories for flaws in RUGGEDCOM ROX II routers, the SINEMA Remote Connect client and server, and
Spectrum Power product.
The industrial giant confirmed that it is not aware of any malicious exploits targeting these flaws.
| [adrotate banner=”9″] | [adrotate banner=”12″] |
(SecurityAffairs – hacking, Siemens)