Vulnerability Spotlight: Remote code execution vulnerabilities in Schneider Electric EcoStruxure
Vulnerabilities mentionedAll →
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2020-7559 | A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unit A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. NVD description · AI analysis pending | 7.5 | 2% | PoC |
| — | |
| CVE-2020-7560 | A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expe A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. NVD description · AI analysis pending | 8.6 | 1% |
| — |
Full article307 words · extracted from blog.talosintelligence.com · click to collapse
Wednesday, December 9, 2020 09:16
Alexander Perez-Palma and Jared Rittle of Cisco Talos discovered this vulnerability. Blog by Jon Munshaw.
Cisco Talos recently discovered two code execution vulnerabilities in Schneider Electric EcoStruxure. An attacker could exploit these vulnerabilities by sending the victim a specially crafted network request or project archive. coStruxure Control Expert (formerly UnityPro) is Schneider Electric's flagship software for program development, maintenance, and monitoring of industrial networks.

In accordance with our coordinated disclosure policy, Cisco Talos worked with Schneider to ensure that these issues are resolved and that an update is available for affected customers.
Vulnerability details
Schneider Electric EcoStruxure Control Expert PLC Simulator Modbus message processing remote code execution vulnerability (TALOS-2020-1140/CVE-2020-7559)
A code execution vulnerability exists in the Modbus message-processing functionality of Schneider Electric EcoStruxure Control Expert PLC Simulator 14.1. A specially crafted network request can lead to remote code execution. An attacker can send a large Modbus request to trigger this vulnerability.
Read the complete vulnerability advisory here for additional information.
Schneider Electric EcoStruxure Control Expert PLC Simulator Modbus message processing remote code execution vulnerability (TALOS-2020-1144/CVE-2020-7560)
A local code execution vulnerability exists in the APX project file processing functionality of Schneider Electric EcoStruxure Control Expert 14.1. The opening of a STA project archive containing a specially crafted APX project file can lead to code execution. An attacker can provide a malicious file to trigger this vulnerability.
Read the complete vulnerability advisory here for additional information.
Versions tested
Talos tested and confirmed that this vulnerability affects Schneider Electric EcoStruxure Control Expert PLC Simulator, version 14.1.
Coverage
The following SNORTⓇ rules will detect exploitation attempts. Note that additional rules may be released at a future date and current rules are subject to change pending additional vulnerability information. For the most current rule information, please refer to your Firepower Management Center or Snort.org.
Snort Rules: 144:1
Text extracted automatically; images, tables and formatting may be missing. Original: https://blog.talosintelligence.com/vulnerability-spotlight-remote-code/