ZeroHour

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2020-6977
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices.

A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5

NVD description · AI analysis pending
6.8<1%
  • ge vivid e95 firmware
  • ge vivid e90 firmware
  • ge vivid s70n firmware
  • +1 more
CVE-2022-23450
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1).

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

NVD description · AI analysis pending
9.836%
  • siemens simatic energy manager basic
  • siemens simatic energy manager pro
CVE-2023-6321
A command injection vulnerability exists in the IOCTL that manages OTA updates.

A command injection vulnerability exists in the IOCTL that manages OTA updates. A specially crafted command can lead to command execution as the root user. An attacker can make authenticated requests to trigger this vulnerability.

NVD description · AI analysis pending
8.83% PoC
  • owletcare cam firmware
  • owletcare cam 2 firmware
  • owletcare kalay platform
CVE-2023-6324
ThroughTek Kalay SDK uses a predictable PSK value in the DTLS session when encountering an unexpected PSK identity

ThroughTek Kalay SDK uses a predictable PSK value in the DTLS session when encountering an unexpected PSK identity

NVD description · AI analysis pending
8.8<1% PoC
  • wyze cam v3 firmware
  • wyze indoor camera se firmware
  • wyze cam firmware
  • +1 more
CVE-2024-1628
OS command injection vulnerabilities in GE HealthCare ultrasound devices

OS command injection vulnerabilities in GE HealthCare ultrasound devices

NVD description · AI analysis pending
8.4<1%
CVE-2024-1629
Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device component

Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device component

NVD description · AI analysis pending
6.2<1%
CVE-2024-1630
Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component

Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component

NVD description · AI analysis pending
7.7<1%
CVE-2024-23912
Out-of-bounds Read vulnerability in Merge DICOM Toolkit C/C++ on Windows.

Out-of-bounds Read vulnerability in Merge DICOM Toolkit C/C++ on Windows. When MC_Open_File() function is used to read a malformed DICOM data, it might result in over-reading memory buffer and could cause memory access violation.

NVD description · AI analysis pending
4.0<1%
CVE-2024-23913
Use of Out-of-range Pointer Offset vulnerability in Merge DICOM Toolkit C/C++ on Windows.

Use of Out-of-range Pointer Offset vulnerability in Merge DICOM Toolkit C/C++ on Windows. When deprecated MC_XML_To_Message() function is used to read a malformed DICOM XML file, it might result in memory access violation.

NVD description · AI analysis pending
4.0<1%
CVE-2024-23914
Use of Externally-Controlled Format String vulnerability in Merge DICOM Toolkit C/C++ on Windows.

Use of Externally-Controlled Format String vulnerability in Merge DICOM Toolkit C/C++ on Windows. When MC_Open_Association() function is used to open DICOM Association and gets DICOM Application Context Name with illegal characters, it might result in an unhandled exception.

NVD description · AI analysis pending
5.7<1%
CVE-2024-27107
Weak account password in GE HealthCare EchoPAC products

Weak account password in GE HealthCare EchoPAC products

NVD description · AI analysis pending
9.6<1%
CVE-2024-27110
Elevation of privilege vulnerability in GE HealthCare EchoPAC products

Elevation of privilege vulnerability in GE HealthCare EchoPAC products

NVD description · AI analysis pending
8.4<1%
Full article759 words · extracted from thehackernews.com · click to collapse

Security researchers have disclosed almost a dozen security flaws impacting the GE HealthCare Vivid Ultrasound product family that could be exploited by malicious actors to tamper with patient data and even install ransomware under certain circumstances.

"The impacts enabled by these flaws are manifold: from the implant of ransomware on the ultrasound machine to the access and manipulation of patient data stored on the vulnerable devices," operational technology (OT) security vendor Nozomi Networks said in a technical report.

The security issues impact the Vivid T9 ultrasound system and its pre-installed Common Service Desktop web application, which is exposed on the localhost interface of the device and allows users to perform administrative actions.

They also affect another software program called EchoPAC that's installed on a doctor's Windows workstation to help them access multi-dimensional echo, vascular, and abdominal ultrasound images.

That being said, successful exploitation of the flaws requires a threat actor to first gain access to the hospital environment and physically interact with the device, after which they can be exploited to achieve arbitrary code execution with administrative privileges.

In a hypothetical attack scenario, a malicious actor could lock out the Vivid T9 systems by implanting a ransomware payload and even exfiltrate or tamper with patient data.

The most severe of the vulnerabilities is CVE-2024-27107 (CVSS score: 9.6), which concerns the use of hard-coded credentials. Other identified shortcomings relate to command injection (CVE-2024-1628), execution with unnecessary privileges (CVE-2024-27110 and CVE-2020-6977), path traversal (CVE-2024-1630 and CVE-2024-1629), and protection mechanism failure (CVE-2020-6977).

The exploit chain devised by Nozomi Networks takes advantage of CVE-2020-6977 to get local access to the device and then weaponizes CVE-2024-1628 to attain code execution.

"However, to speed up the process, [...] an attacker may also abuse the exposed USB port and attach a malicious thumb drive that, by emulating the keyboard and mouse, automatically performs all necessary steps at faster-than-human speed," the company said.

Alternatively, an adversary could obtain access to a hospital's internal network using stolen VPN credentials gathered via other means (e.g., phishing or data leak), scan for vulnerable installations of EchoPAC, and then exploit CVE-2024-27107 to gain unfettered access to the patient's database, effectively compromising its confidentially, integrity, and availability.

GE HealthCare, in a set of advisories, said "existing mitigations and controls" reduce the risks posed by these flaws to acceptable levels.

"In the unlikely event a malicious actor with physical access could render the device unusable, there would be clear indicators of this to the intended user of the device," it noted. "The vulnerability can only be exploited by someone with direct, physical access to the device."

The disclosure comes weeks after security flaws were also uncovered in the Merge DICOM Toolkit for Windows (CVE-2024-23912, CVE-2024-23913, and CVE-2024-23914) that could used to trigger a denial-of-service (DoS) condition on the DICOM service. The issues have been addressed in version v5.18 [PDF] of the library.

It also follows the discovery of a maximum-severity security flaw in the Siemens SIMATIC Energy Manager (EnMPro) product (CVE-2022-23450, CVSS score: 10.0) that could be exploited by a remote attacker to execute arbitrary code with SYSTEM privileges by sending maliciously crafted objects.

"An attacker successfully exploiting this vulnerability could remotely execute code and gain complete control over an EnMPro server," Claroty security researcher Noam Moshe said.

Users are highly recommended to update to version V7.3 Update 1 or later as all versions prior to it contain the insecure deserialization vulnerability.

Security weaknesses have also been unearthed in the ThroughTek Kalay Platform integrated within Internet of Things (IoT) devices (from CVE-2023-6321 through CVE-2023-6324) that allows an attacker to escalate privileges, execute commands as root, and establish a connection with a victim device.

"When chained together, these vulnerabilities facilitate unauthorized root access from within the local network, as well as remote code execution to completely subvert the victim device," Romanian cybersecurity company Bitdefender said. "Remote code execution is only possible after the device has been probed from the local network."

The vulnerabilities, patched as of April 2024 following responsible disclosure in October 2023, have been found to impact baby monitors, and indoor security cameras from vendors like Owlet, Roku, and Wyze, permitting threat actors to daisy-chain them in order to execute arbitrary commands on the devices.

"The ramifications of these vulnerabilities extend far beyond the realm of theoretical exploits, as they directly impact on the privacy and safety of users relying on devices powered by ThroughTek Kalay," the company added.

Found this article interesting? Follow us on Google News, Twitter and LinkedIn to read more exclusive content we post.

Text extracted automatically; images, tables and formatting may be missing. Original: https://thehackernews.com/2024/05/researchers-uncover-11-security-flaws.html