75% Of Medical Infusion Pumps Affected By Known Vulnerabilities
Vulnerabilities mentionedAll →
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2016-9355 +1 in the same advisory: …8375 | An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7. An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7. An unauthorized user with physical access to an Alaris 8015 PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive technical data by disassembling an Alaris 8015 PC unit and accessing the device's flash memory. Older software versions of the Alaris 8015 PC unit, Version 9.5 and prior versions, store wireless network authentication credentials and other sensitive technical data on the affected device's removable flash memory. Being able to remove the flash memory from the affected device reduces the risk of detection, allowing an attacker to extract stored data at the attacker's convenience. NVD description · AI analysis pending | 5.3 group max | <1% |
| — | ||
| CVE-2019-12255 | Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow. NVD description · AI analysis pending | 9.8 | 75% | PoC |
| — | |
| CVE-2019-12264 | Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component. Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component. NVD description · AI analysis pending | 7.1 | 8% |
| — | ||
| CVE-2020-12043 | The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operation The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. NVD description · AI analysis pending | 9.8 group max | 2% |
| — | ||
| CVE-2020-25165 | BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a ne BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD Alaris PC Unit by modifying the configuration headers of data in transit. A denial-of-service attack could lead to a drop in the wireless capability of the BD Alaris PC Unit, resulting in manual operation of the PC Unit. NVD description · AI analysis pending | 7.5 | 2% |
| — |
Full article538 words · extracted from securityaffairs.com · click to collapse

Researchers analyzed more than 200,000 network-connected medical infusion pumps and discovered that over 100,000 of them are vulnerable.
Researchers from Palo Alto Networks have analyzed more than 200,000 medical infusion pumps on the networks of hospitals and other healthcare organizations and discovered that 75% are affected by known vulnerabilities that could be exploited by attackers.
“We reviewed crowdsourced data from scans of more than 200,000 infusion pumps on the networks of hospitals and other healthcare organizations using IoT Security for Healthcare from Palo Alto Networks.” reads the report published by Palo Alto Networks. “An alarming 75 percent of infusion pumps scanned had known security gaps that put them at heightened risk of being compromised by attackers. These shortcomings included exposure to one or more of some 40 known cybersecurity vulnerabilities and/or alerts that they had one or more of some 70 other types of known security shortcomings for IoT devices.”

One of the most interesting findings that emerged from the report is that 52% of all infusion pumps analyzed by the experts were susceptible to two vulnerabilities publicly disclosed in 2019. These data are disconcerting considering that the average infusion pump has a life of eight to 10 years.
The following table reports the 10 most prevalent issues that emerged from the scan of network-connected medical devices.
CVE | Severity (Score) | % of analyzed pumps with CVEs | |
| 1 | CVE-2019-12255 | 9.8 (Critical) | 52.11% |
| 2 | CVE-2019-12264 | 7.1 (High) | 52.11% |
| 3 | CVE-2016-9355 | 5.3 (Medium) | 50.39% |
| 4 | CVE-2016-8375 | 4.9 (Medium) | 50.39% |
| 5 | CVE-2020-25165 | 7.5 (High) | 39.54% |
| 6 | CVE-2020-12040 | 9.8 (Critical) | 17.83% |
| 7 | CVE-2020-12047 | 9.8 (Critical) | 15.23% |
| 8 | CVE-2020-12045 | 9.8 (Critical) | 15.23% |
| 9 | CVE-2020-12043 | 9.8 (Critical) | 15.23% |
| 10 | CVE-2020-12041 | 9.8 (Critical) | 15.23% |
Table 1. The top 10 most prevalent vulnerabilities found in the more than 200,000 inf
Experts grouped the issues is several categories, including leakage of sensitive information, unauthorized access and buffer overflow. Palo Alto Networks reported that some issues are related to third-party cross-platform libraries used by the devices, such as network stacks. CVE-2019-12255 and CVE 2019-12264 vulnerabilities in the TCP/IP stack IPNet.
Both flaws affect 52% of the analyzed infusion pumps, approximately more than 104,000 devices.
Palo Alto Networks recommends healthcare providers adopt a proactive security strategy to prevent attacks, below are some key capabilities to consider when evaluating IoMT security strategies and technologies for healthcare:
- Accurate discovery and inventory
- Holistic risk assessment
- Apply risk reduction policies
- Prevent Threats
“Among the 200,000 infusion pumps we studied, 75% were vulnerable to at least one vulnerability or threw up at least one security alert. While some of these vulnerabilities and alerts may be impractical for attackers to take advantage of unless physically present in an organization, all represent a potential risk to the general security of healthcare organizations and the safety of patients – particularly in situations in which threat actors may be motivated to put extra resources into attacking a target.” concludes the report.
With attack surfaces widening and attack vectors becoming more refined than ever before, now’s the time for healthcare organizations to define medical device security with a new level of sophistication. “
Follow me on Twitter: @securityaffairs and Facebook