ZeroHour

Search: “web”

261 stories

Progress Software security advisory (AV26-875)

Canada's Cyber Centre warns Progress Telerik UI for ASP.NET AJAX before 2026.3.812 is affected by path traversal and upload tampering flaws, urging updates.

The Canadian Centre for Cyber Security issued advisory AV26-875 on September 2, 2026, covering vulnerabilities in Progress Software Telerik UI for ASP.NET AJAX prior to version 2026.3.812. Two flaws are listed: CVE-2026-18672, a path traversal in the Telerik Web Forms RadImageEditor, and CVE-2026-19219, a DialogHandler UploadPaths tampering vulnerability. Administrators are encouraged to review the provided links and apply available updates.

UI DoS attack

FortiOS web interface is vulnerable to unauthenticated slow HTTP denial-of-service attacks via crafted requests (CVSS 5.0).

Fortinet advisory FG-IR-26-162 details an unbounded resource allocation flaw (CWE-770) in FortiOS, scored CVSSv3 5.0. An unauthenticated attacker can launch a slow HTTP denial-of-service attack against the FortiOS web interface using crafted HTTP requests. The advisory was revised on 2026-08-12 and does not state that exploitation has been observed.

Fortinet PSIRT · Aug 12, 2026Advisory

Cisco Secure Firewall Management Center Software Static Credential Vulnerability

Cisco warns of static low-privileged credentials in Secure Firewall Management Center's web interface, letting unauthenticated remote attackers log in and access sensitive data.

Cisco disclosed a vulnerability in the web interface of Secure Firewall Management Center (FMC) Software caused by the presence of static credentials for a low-privileged account. An unauthenticated remote attacker could log in to an affected device using the static account and access sensitive data within impacted systems. The attack surface is reduced when the FMC management interface does not have public internet access.

Cisco Security Advisories · Aug 11, 2026Advisory

Oracle Corporation security advisory (AV26-929)

CCCS relays Oracle's September 2026 Critical Patch Update fixing vulnerabilities across WebLogic, Database, E-Business Suite, PeopleSoft, Siebel, and dozens more products.

The Canadian Centre for Cyber Security (AV26-929) relays Oracle's September 2026 Critical Security Patch Update, which addresses vulnerabilities in dozens of product families as of September 15, 2026. Affected products include Oracle WebLogic Server, Database Server, E-Business Suite, Fusion Middleware, PeopleSoft Enterprise, Siebel Applications, GraalVM, VirtualBox, Coherence, and numerous banking and communications suites. The bulletin lists no CVE identifiers and encourages administrators to review Oracle's advisory and apply patches.

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

Microsoft security advisory – September 2026 monthly rollup (AV26-896) – Update 1

Canada's Cyber Centre relays Microsoft's September 2026 rollup; CISA added exploited zero-days CVE-2026-85880 and CVE-2026-81963 to KEV.

Advisory AV26-896 from the Canadian Centre for Cyber Security summarizes Microsoft's September 2026 monthly security rollup, listing affected products across Windows, Office, .NET, Azure, Exchange and SQL Server. It notes Microsoft confirmed CVE-2026-81963 and CVE-2026-85880 have been exploited. On September 8, 2026, CISA added both CVEs to its Known Exploited Vulnerabilities catalog, and administrators are urged to apply the updates.

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

CISA Red Team Compromised Two Critical Infrastructure Orgs, One Detected Nothing

CISA red teams fully compromised two critical infrastructure orgs with similar tradecraft; one detected nothing, the other contained phishing within minutes.

CISA advisory AA26-237A, 'A Tale of Two SOCs,' describes two simultaneous red team assessments of a Government Services organization and a Water and Wastewater Systems organization, both compromised to the domain level. Organization A never detected the intrusion, enabled by default credentials, a misconfigured AD CS template (ESC1), cleartext credentials, non-expiring static AWS keys, and over-permissioned Entra ID applications. Organization B detected and isolated phishing within 2-20 minutes, though the red team still reached krbtgt via DCSync from cleartext SCCM credentials. CISA attributes the outcome gap to people and processes rather than the security tools themselves.

The Hacker News · 21d agoAdvisory

Cisco Industrial Ethernet 1000 Series Switches Stored Cross-Site Scripting Vulnerability

Cisco fixed a stored cross-site scripting flaw in Industrial Ethernet 1000 series switches exploitable by authenticated remote users.

Insufficient validation of user-supplied input in the web-based management interface of Cisco Industrial Ethernet 1000 Series Switches allows stored XSS. An authenticated remote attacker can inject malicious code into specific interface pages and execute arbitrary script in another user's context. Exploitation requires valid credentials; Cisco has released software updates.

Cisco Security Advisories · 28d agoAdvisory