CISA promotes a fresh way to deter cyberattackers: Lie to them
CISA issued first-time guidance advising critical infrastructure operators to deploy honeypots, honeytokens, and decoys to detect and distract intruders.
CISA published 'Using Cyber Decoys to Strengthen Detection and Response,' a 22-page guide marking the agency's first guidance on decoys such as honeypots and honeytokens. Acting executive director Chris Butera described decoys as a low-cost, high-fidelity way to detect adversaries already inside networks, complementing zero-trust and assume-compromise approaches. The guidance covers decoy principles, definitions, deployment scenarios, and is aimed especially at resource-constrained critical infrastructure sectors.
Water sector passes, government sector fails attempts to spot and halt simulated CISA attack
CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.
CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.
AI-fueled attacks pose ‘active threat’ to water, other sectors, U.S. agencies warn
NSA, CISA, FBI, DOE and EPA warn hackers are using AI-generated scripts to actively attack Siemens S7 PLCs across critical-infrastructure sectors.
A joint cybersecurity advisory from the NSA, CISA, FBI, Department of Energy and EPA warns of an active threat campaign targeting water, food, energy, chemical, manufacturing and commercial facilities via Siemens S7 Series programmable logic controllers. The actors use internet scanning to find exposed or poorly protected PLCs, then deploy AI-generated exploitation scripts disguised as legitimate monitoring tools, an OT first that dramatically lowers the expertise required for ICS attacks. Siemens says no new S7 vulnerabilities are involved, only exploitation of misconfigurations, and it is coordinating with CISA's ProductCERT. The warning follows a joint FBI-EPA advisory confirming attacks at water and wastewater utilities in at least 12 states since July 27.