ZeroHour

Search: “Secure Connect Gateway”

9 stories

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

7th September – Threat Intelligence Report

Check Point weekly bulletin: exploited SonicWall SMA 1000 zero-days (CVE-2026-83548/49), JFrog Artifactory auth bypass, and a 2.8M-patient Baylor Genetics breach.

Check Point's weekly bulletin covers breaches including Thomson Reuters' C-Track platform (court records across 11 US states and Canada), Baylor Genetics (2.8M patients and employees, SSNs included), Hit casinos in Slovenia, and Dropbox (~5,000 accounts via abused Lenovo email verification). SonicWall patched two exploited SMA 1000 zero-days, including CVE-2026-83548, a CVSS 10.0 pre-authentication SSRF, while JFrog fixed exploited authentication bypass CVE-2026-82329 (CVSS 9.8). Malware and actor coverage includes Gambling Goblin, JSCeal, Mirage Kitten's NodeRabbit/PollCat campaign, and DPRK Contagious Interview macOS activity, plus a FalconFlank privilege-escalation PoC against CrowdStrike Falcon.