CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

Oracle Critical Security Update – 673 Vulnerabilities Patched Across Product Families

Oracle's September 2026 Critical Patch Update ships 673 patches across 17 product families, including 100+ critical and 240+ remotely exploitable flaws.

Oracle's September 2026 Critical Security Patch Update ships 673 patches covering 672 unique CVEs, with more than 130 additional CVEs resolved through bundled fixes, pushing the effective total past 800. Over 100 flaws are critical severity and more than 240 are remotely exploitable without authentication. Oracle E-Business Suite received 159 fixes, Fusion Middleware 153 (78 unauthenticated and network-exploitable), and Hyperion 102. No in-the-wild exploitation of these specific flaws is reported, but Oracle cites CISA's earlier 72-hour remediation order for actively exploited CVE-2026-21962 (CVSS 10.0).

Cyber Security Newsupdated · 14h agofirst · 20h agoAdvisory 3 sourcesCVE-2026-219621

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

Android Security Update September 2026 – Fix for Critical Flaws that Enable RCE Attacks

Google's September 2026 Android bulletin fixes over 30 critical flaws, including no-interaction system RCEs, a TIPC kernel RCE and a Qualcomm closed-source bug

Google's Android Security Bulletin for September 2026 (patch levels 2026-09-01 and 2026-09-05) fixes numerous critical System remote code execution flaws, including CVE-2026-28604, CVE-2026-28618, CVE-2026-28639, CVE-2026-28662, CVE-2026-49882, CVE-2026-49884, CVE-2026-49919 and CVE-2026-49921, none requiring user interaction or additional privileges. It also addresses critical kernel issues including a TIPC RCE (CVE-2026-52993) and elevation-of-privilege flaws in NFC and protected KVM, plus a critical Qualcomm closed-source component flaw (CVE-2026-25289). Affected versions span Android 14 through 17; the 2026-09-05 patch level extends coverage to Android TV and chipset components, with high-severity fixes for Arm Mali, PowerVR, MediaTek, Unisoc and Qualcomm components.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Oracle Critical Security Patch Update, September 2026 Review

Oracle's September 2026 Critical Patch Update fixes 673 vulnerabilities, including 104 critical, with many remotely exploitable in E-Business Suite and Fusion Middleware.

Oracle released 673 security patches in its September 2026 Critical Patch Update: 104 rated critical, 503 high, and 59 medium. Oracle E-Business Suite received the most patches (159, 24% of total), with 19 exploitable without credentials including CVE-2026-83327, CVE-2026-83452, and CVE-2026-83462 at CVSS 9.8. Fusion Middleware received 153 patches with 78 remotely exploitable without authentication, and 41 patches address third-party open-source component flaws. Qualys published detection QIDs for vulnerable assets.

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

ZTNA Portal Improper Certificate Validation

Fortinet fixed an improper certificate validation flaw (CVSS 7.3) in FortiOS and FortiProxy Agentless ZTNA portal enabling unauthenticated man-in-the-middle attacks on backend traffic.

Fortinet advisory FG-IR-26-174 discloses an improper certificate validation vulnerability (CWE-295) in the FortiOS and FortiProxy Agentless ZTNA portal, rated CVSSv3 7.3. A remote and unauthenticated attacker can perform a man-in-the-middle attack on the communication channel between the ZTNA portal and the backend destination website. The advisory was revised on 2026-09-08.

Fortinet PSIRT · 9d agoAdvisory