ZeroHour

Search: “energy”

12 stories

AI-fueled attacks pose ‘active threat’ to water, other sectors, U.S. agencies warn

NSA, CISA, FBI, DOE and EPA warn hackers are using AI-generated scripts to actively attack Siemens S7 PLCs across critical-infrastructure sectors.

A joint cybersecurity advisory from the NSA, CISA, FBI, Department of Energy and EPA warns of an active threat campaign targeting water, food, energy, chemical, manufacturing and commercial facilities via Siemens S7 Series programmable logic controllers. The actors use internet scanning to find exposed or poorly protected PLCs, then deploy AI-generated exploitation scripts disguised as legitimate monitoring tools, an OT first that dramatically lowers the expertise required for ICS attacks. Siemens says no new S7 vulnerabilities are involved, only exploitation of misconfigurations, and it is coordinating with CISA's ProductCERT. The warning follows a joint FBI-EPA advisory confirming attacks at water and wastewater utilities in at least 12 states since July 27.

CyberScoop · 27d agoAdvisory in the wild1

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 28d agoAdvisory in the wild

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 14d agoAdvisoryCVE-2026-4827

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 14d agoAdvisoryCVE-2026-75925

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 14d agoAdvisoryCVE-2026-78012