ZeroHour

Search: “encoder-decoder”

3 stories in the last 30d

Unified CT and MRI Pancreas Segmentation for Label-Efficient Cross-Modality Subregion Transfer

Domain-adversarial nnU-Net trained on 4,604 CT/MRI scans achieves 87.31% Dice pancreas segmentation with label-efficient subregion transfer.

A unified 3D pancreas segmentation framework applies domain-adversarial learning to 4,604 heterogeneous CT and MRI scans, aligning CT-MRI features via a latent domain discriminator on a shared nnU-Net encoder-decoder. Whole-pancreas segmentation reaches 87.31% Dice in-distribution and 84.20%-88.09% across external OOD datasets. The transferred encoder achieves 80.53% Dice on MRI and 83.05% on CT for downstream head-body-tail subregion segmentation using only limited MRI subregion annotations.

arXiv cs.AI / cs.LG / cs.CL · 5d agoAI research

TART: A Modular Tool for Technique-Aware Audio-to-Tablature Guitar Transcription

TART pipeline transcribes guitar audio to tablature with fingering and technique labels, outperforming prior baselines by up to 8.5 Tab F1 points.

TART is a modular four-stage pipeline for audio-to-tablature guitar transcription, combining an audio-to-MIDI transcription model, an expressive technique classifier, an audio-conditioned T5 encoder-decoder for string-fret assignment, and an automated tablature generator. In zero-shot evaluation on GuitarSet, EGDB, and two noisy augmented benchmarks, it averages 81.35% audio-to-MIDI F50 (+6.67 over the best baseline), 71.8% string-fret Tab F1 (+8.5), and 54.08% end-to-end Tab F1. The authors state it is the first framework to generate tablature with both fingering and expressive technique annotations directly from guitar audio.

arXiv cs.AI / cs.LG / cs.CL · 6d agoAI research2

TransNormal-2: Geometry-Grounded Rectified Flow with Edge-Aware Decoding for Precise Normal Estimation

TransNormal-2 improves monocular surface-normal estimation by fixing VAE edge degradation with geometry-aware losses and refinement, matching MoGe-2 with 1.4% of annotations.

TransNormal-2 is a FLUX.2-based rectified-flow framework for monocular surface-normal estimation with single-step deterministic inference. The authors quantify that VAE 8x spatial compression introduces 1.3-8.5 degrees of mean angular error even on ground-truth normals, with edge error up to 2.8x the global error. The method adds geometry-aware pixel-space losses and an RGB-guided Geometric Refinement Module to correct boundary-localized decoding errors. It matches or exceeds MoGe-2 on all eight reported metrics using only 1.4% as many task-specific annotations, and cuts transparent-object MAE by 4.2 degrees on ClearGrasp and 3.1 degrees on ClearPose.

Hugging Face daily papers · 11d agoAI research