ZeroHour

Search: “baseline”

3 stories in the last 30d

CVE-2026-16232: Check Point SmartConsole Auth Bypass

Check Point SmartConsole authentication bypass CVE-2026-16232 grants unauthenticated attackers full admin access; actively exploited and added to CISA KEV.

CVE-2026-16232 is an improper authentication flaw (CWE-287) in the Check Point SmartConsole login process that lets an unauthenticated remote attacker obtain an application token and authenticate with full administrative privileges. Exploitation requires the Management Server to be internet-reachable and the Trusted Clients list not restricted to specific administrator addresses. Check Point confirmed active exploitation affecting a small number of customers, and the vulnerability has been added to the CISA Known Exploited Vulnerabilities catalog. A hotfix is available via Check Point advisory sk185169.

Hackers Chain Two New SonicWall Zero-Day Vulnerabilities

SonicWall warns two zero-days (CVE-2026-83548 SSRF, CVE-2026-83549 post-auth RCE) in SMA1000 appliances are being actively exploited.

A September 1 SonicWall advisory discloses actively exploited zero-days in SMA1000 appliance models 6210, 7210 and 8200v, affecting platform-hotfix versions 12.4.3-03453 and 12.5.0-02835 and older. CVE-2026-83548 (CVSS 10.0) is a pre-authentication SSRF in the Appliance Work Place interface via an unintended alternate access path; CVE-2026-83549 (CVSS 7.8) is post-authentication OS command injection enabling RCE in the Appliance Management Console. SonicWall urges hotfix upgrades, IOC checks with SonicWall support, and re-imaging plus credential and TOTP resets if compromise is found.

NSA, CISA, FBI, DOE, and EPA Warn of Active AI

Five US agencies warn of active AI-assisted attacks on internet-exposed Siemens S7 PLCs across critical infrastructure, using disguised snap7 scripts for pre-positioning reconnaissance.

NSA, CISA, FBI, DOE, and EPA issued joint advisory CISA AA26-231A warning of an active hacking campaign against Siemens S7-series PLCs, from S7-200 through S7-1500 F-series, across US critical infrastructure. Threat actors use internet scanning services such as Censys and ZoomEye to locate exposed controllers, then perform read operations over S7comm on TCP port 102 using the legitimate snap7.dll and python-snap7 libraries, disguising AI-generated exploitation scripts as monitoring tools. The agencies assess the activity as pre-positioning ahead of possible process disruption, equipment damage, or safety incidents in Energy, Water, Critical Manufacturing, Chemical, Food and Agriculture, and Commercial Facilities sectors.

Security Affairs · 27d agoExploit / PoC in the wild