Hackers Actively Exploiting Gitea n-day RCE Vulnerability in the Wild to Hijack Instances
Chinese-speaking Red Heron actors mass-exploit Gitea n-day RCE CVE-2026-60004 to steal source code, credentials, and pivot into victim networks.
Acronis Threat Research Unit reports active in-the-wild exploitation of Gitea RCE CVE-2026-60004 (CVSS 9.8, versions 1.17-1.27.0, fixed in 1.27.1) by a Chinese-speaking actor dubbed Red Heron. The actor scanned 1,386 Gitea servers across seven countries, held a separate list of 477 Taiwan-based targets, and confirmed victims in Canada, Argentina, Taiwan, the US, and Sri Lanka. Intrusions deployed the JITTERLY Linux implant with the SIXZUT LD_PRELOAD rootkit, stole password hashes and SSH keys, and in one case gained root admin access to a three-node Proxmox cluster.
Marimo RCE Flaw Lets Hackers Steal AWS Credentials and Pivot to Bastion Host in 8 Seconds
Attacker exploited unauthenticated marimo WebSocket RCE CVE-2026-39987 to steal AWS credentials and SSH into a bastion host in eight seconds.
Sysdig Threat Research Team documented a real intrusion exploiting CVE-2026-39987 in marimo (versions up to 0.20.4, fixed in 0.23.0), where the unauthenticated /terminal/ws WebSocket endpoint exposed an interactive shell. Within eight seconds the attacker pulled AWS credentials from Redis, extracted an SSH private key from AWS Secrets Manager via Boto3, and authenticated to a bastion host; over nine hours the operator ran 850+ commands using a staged custom Python toolkit. Blocked EC2 Instance Connect attempts (SendSSHPublicKey to placeholder instance i-0000000000000000) provide a high-confidence detection signal.
CISA Warns Water Utilities: Find Your Exposed PLCs Before Attackers Do
CISA urged water utilities to secure internet-exposed PLCs after July 2026 attacks compromised over 100 US water and wastewater systems, suspected Iran-linked.
CISA's exposure-reduction guidance, published August 21, follows July 2026 attacks in which threat actors remotely accessed PLCs connected directly through cellular modems, changed device IP addresses and passwords, and in some cases disabled alarms and shutdown processes without notifying operators. Iran is the suspected actor, though officials stopped short of formal attribution. CISA recommends routing remote access through centrally managed secure gateways, phishing-resistant MFA, unique credentials, and external scanning of industrial protocols such as Modbus, EtherNet/IP, DNP3, BACnet and OPC UA.