ZeroHour

Source: Palo Alto Unit 42

3 stories in the last 30d

Multiple Vulnerabilities Discovered in a SCADA System

Unit 42 details five vulnerabilities (CVSS 7.0-7.8) in ICONICS Suite SCADA software enabling privilege escalation and DoS.

Unit 42 discovered five vulnerabilities (CVE-2024-1182, CVE-2024-7587, CVE-2024-8299, CVE-2024-8300, CVE-2024-9852) in ICONICS Suite versions 10.97.2 and earlier for Windows during a 2024 security assessment. The flaws, rated CVSS 7.0-7.8, allow DLL hijacking, privilege escalation, information disclosure, denial-of-service and potentially full system compromise. ICONICS Suite is a SCADA solution with hundreds of thousands of installations in over 100 countries, widely used in critical infrastructure, and several dozen servers are internet-exposed per Unit 42 telemetry. ICONICS released patches and advisories with workarounds in 2024.

Privileged File System Vulnerability Present in a SCADA System

Unit 42 details CVE-2025-0921 (CVSS 6.5), a privileged file operations flaw in Iconics Suite enabling DoS and privilege escalation.

Unit 42 disclosed CVE-2025-0921 (CVSS 6.5), an execution-with-unnecessary-privileges flaw in the Pager Agent of the AlarmWorX64 MMX feature of Mitsubishi Electric Iconics Digital Solutions GENESIS64. Attackers could misuse privileged file system operations to corrupt critical binaries, causing denial-of-service or integrity loss on vulnerable SCADA systems. The analysis demonstrates a chain with CVE-2024-7587, which grants excessive permissions to the C:\ProgramData\ICONICS directory via the GenBroker32 installer. Iconics released an advisory with a workaround that addresses the reported issues.

3 Vulnerabilities Found on AvertX IP Cameras

Unit 42 disclosed three vulnerabilities (CVE-2020-11623/4/5) in AvertX HD838 and 438IR IP cameras; AvertX has released patches.

Palo Alto Networks Unit 42 researchers found three vulnerabilities in AvertX HD838 and 438IR outdoor surveillance cameras, which are rebranded Hikvision products: CVE-2020-11625 (user enumeration), CVE-2020-11624 (weak password requirements), and CVE-2020-11623 (exposed dangerous method/function). User enumeration responses facilitate brute-force attacks, the default admin credentials (admin/1234) are never enforced to change, and physical access to an exposed UART interface allows bootloader access and configuration modification. AvertX released a patch, removed the UART connector, and disabled the interface in the latest production batch.