Multiple Vulnerabilities Discovered in a SCADA System

Unit 42 details five vulnerabilities (CVSS 7.0-7.8) in ICONICS Suite SCADA software enabling privilege escalation and DoS.

Unit 42 discovered five vulnerabilities (CVE-2024-1182, CVE-2024-7587, CVE-2024-8299, CVE-2024-8300, CVE-2024-9852) in ICONICS Suite versions 10.97.2 and earlier for Windows during a 2024 security assessment. The flaws, rated CVSS 7.0-7.8, allow DLL hijacking, privilege escalation, information disclosure, denial-of-service and potentially full system compromise. ICONICS Suite is a SCADA solution with hundreds of thousands of installations in over 100 countries, widely used in critical infrastructure, and several dozen servers are internet-exposed per Unit 42 telemetry. ICONICS released patches and advisories with workarounds in 2024.

Privileged File System Vulnerability Present in a SCADA System

Unit 42 details CVE-2025-0921 (CVSS 6.5), a privileged file operations flaw in Iconics Suite enabling DoS and privilege escalation.

Unit 42 disclosed CVE-2025-0921 (CVSS 6.5), an execution-with-unnecessary-privileges flaw in the Pager Agent of the AlarmWorX64 MMX feature of Mitsubishi Electric Iconics Digital Solutions GENESIS64. Attackers could misuse privileged file system operations to corrupt critical binaries, causing denial-of-service or integrity loss on vulnerable SCADA systems. The analysis demonstrates a chain with CVE-2024-7587, which grants excessive permissions to the C:\ProgramData\ICONICS directory via the GenBroker32 installer. Iconics released an advisory with a workaround that addresses the reported issues.

ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws

September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.

Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.