ZeroHour

Search: “cisa”

7 stories in the last 30d

CareCam Pro IP Cameras

CISA advisory details hard-coded bootloader credential CVE-2026-85083 in ANJIA AJL33PC0801 CareCam Pro cameras, allowing physical-access firmware compromise.

CISA ICS advisory ICSA-26-251-01 describes CVE-2026-85083, a hard-coded credential (CWE-798) used for bootloader authentication in the ANJIA AJL33PC0801 CareCam Pro IP camera. An attacker with physical access could gain privileged bootloader access and modify firmware and configuration, potentially fully compromising the device. The flaw scores 6.8 on CVSS 3.1 (7.0 on CVSS 4.0), is not remotely exploitable, and no public exploitation has been reported. Affected firmware is linux_linux_202008261138_svn13796 with U-Boot 2010.06; the vendor is headquartered in China with worldwide deployments.

CISA Advisories · 8d agoAdvisoryCVE-2026-85083

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 13d agoAdvisoryCVE-2026-77477

Applied Systems Engineering ASE2000 V2 Communications Test Set

CISA warns ASE2000 V2 test sets allow arbitrary file read/write, outbound request abuse, and TLS peer impersonation; version 2.38 fixes both vulnerabilities.

CISA published ICS advisory ICSA-26-239-04 for Applied Systems Engineering (Kalkitech) ASE2000 V2 Communications Test Set versions 2.25 through 2.37. Exploitation could allow reading or writing arbitrary local files, forcing outbound network requests, or intercepting the TLS connection to impersonate the trusted peer and read or modify protected communications. Vendor ASE/Kalkitech provides upgraded version 2.38, which also updates the bundled log4net library, fixing both vulnerabilities; customers are advised to upgrade.

CISA Advisories · 20d agoAdvisory

Mitsubishi Electric CNC Series (Update A)

CISA's updated ICS advisory details CVE-2025-2399, an out-of-bounds read in Mitsubishi Electric CNC series that lets a remote attacker cause a denial-of-service condition.

CISA released Update A of ICS advisory ICSA-26-078-05 covering Mitsubishi Electric CNC series controllers. The vulnerability CVE-2025-2399 is an out-of-bounds read that a remote attacker can exploit to trigger a denial-of-service condition. Affected products include M800VW, M800VS, M80V, M80VW, M800W, M800S and M80 series controllers up to specified firmware revisions. No exploitation is reported in the advisory.

CISA Advisories · 20d agoAdvisoryCVE-2025-2399

Mitsubishi Electric Multiple FA Products (Update D)

CISA warns Mitsubishi Electric CC-Link IE TSN remote I/O modules are vulnerable to denial-of-service via crafted UDP packets (CVE-2025-3511).

CISA published Update D of advisory ICSA-25-128-03 covering Mitsubishi Electric factory automation products. Affected products include CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, and NZ2GN2S1-32DT at firmware version 09 or earlier (CVE-2025-3511). A remote attacker can send a specially crafted UDP packet to cause denial-of-service conditions, timeout errors, or communication delays on the affected products.

CISA Advisories · 20d agoAdvisoryCVE-2025-3511

Rockwell Automation OTTO Fleet Manager

CISA warns Rockwell Automation OTTO Fleet Manager (CVE-2026-75112, CVSS 6.8) uses insufficiently costly password hashing, easing offline brute-force attacks.

CISA published ICS advisory ICSA-26-239-03 for Rockwell Automation OTTO Fleet Manager versions 2.36.2 and earlier (CVE-2026-75112, CVSS v3 6.8). The flaw involves use of a password hash with insufficient computational effort, reducing the cost for an attacker to perform offline brute-force attacks against stored password hashes. Deployments span critical manufacturing and transportation systems sectors worldwide, with company headquarters in the United States.

CISA Advisories · 20d agoAdvisoryCVE-2026-75112

Researchers Use Claude to Port Pre-Auth RCE Exploit From One PLC Model to Another

Forescout used Anthropic's Claude to port a working pre-auth RCE exploit for CVE-2021-31886 between WAGO PLCs, executing ARM shellcode on live hardware.

Forescout Vedere Labs used Claude interactively to port an RCE exploit for CVE-2021-31886, a CVSS 9.8 stack buffer overflow in the Nucleus FTP server's USER command, from a WAGO 750-852 to a WAGO 750-831 PLC, running attacker-supplied ARM shellcode. The final RCE stage cost $535.74 in API usage over 8 hours 32 minutes, and a follow-up attempt to build a C2 implant permanently bricked the device. CERT@VDE lists many Nucleus V1-based WAGO models as vulnerable with no updates available; Siemens plans no Nucleus NET remediation. The work follows a joint NSA/CISA/FBI/DOE/EPA advisory warning of AI-generated exploitation scripts targeting internet-exposed Siemens S7 PLCs.

The Hacker News · 15d agoResearchCVE-2021-318862