ZeroHour

Search: “ics-remote-access”

27 stories

Smart search ranks by meaning as well as keywords (one row per story, last 45 days).

Cisco Warns of Ongoing Exploitation of Critical Email Gateway Zero-Day

Cisco Secure Email Gateway zero-day CVE-2026-76461 (CVSS 9.8) is actively exploited for root command execution; CISA added it to KEV.

Cisco disclosed critical zero-day CVE-2026-76461 (CVSS 9.8) in Secure Email Gateway, remotely exploitable without authentication via crafted emails containing malicious SQL statements, leading to arbitrary command execution with root privileges. The flaw affects physical and virtual appliances regardless of configuration and has no workarounds. Cisco PSIRT confirmed active exploitation, and CISA added the CVE to its KEV catalog on September 14 with a federal remediation deadline of September 17. Admins should review mail_logs for suspicious SQL statements such as 'COPY.*TO PROGRAM'.

Security Affairsupdated · 14h agofirst · 22h agoExploit / PoC in the wild 15 sourcesCVE-2026-764613· 2 reads

Critical NetScaler Vulnerability Exploited in Attacks

CISA added critical Citrix NetScaler flaw CVE-2026-19490 (CVSS 9.3) to its KEV catalog after confirming exploitation of gateway and AAA virtual servers in the wild.

CISA warned that threat actors are exploiting CVE-2026-19490, a critical-severity flaw (CVSS 9.3) affecting NetScaler ADC and NetScaler Gateway appliances configured as a gateway (SSL VPN, ICA Proxy, CVPN, RDP Proxy) or AAA virtual server. Citrix patched the bug on August 19, and Rapid7 warned it is remotely exploitable without authentication. Sensor data from Previdian shows exploitation ongoing since at least September 3, one day after a public exploit appeared on GitHub, with matching requests observed from three IPs across three countries. CISA added the flaw to its Known Exploited Vulnerabilities catalog, giving federal agencies three days to patch under BOD 26-04.

SecurityWeekupdated · 5d agofirst · 5d agoExploit / PoC in the wild 5 sourcesCVE-2026-194902· 2 reads

Cisco Industrial Ethernet 1000 Series Switches Stored Cross-Site Scripting Vulnerability

Cisco fixed a stored cross-site scripting flaw in Industrial Ethernet 1000 series switches exploitable by authenticated remote users.

Insufficient validation of user-supplied input in the web-based management interface of Cisco Industrial Ethernet 1000 Series Switches allows stored XSS. An authenticated remote attacker can inject malicious code into specific interface pages and execute arbitrary script in another user's context. Exploitation requires valid credentials; Cisco has released software updates.

Cisco Security Advisories · 27d agoAdvisory

ZDI-26-581: Cisco Identity Services Engine invokeScript Command Injection Remote Code Execution Vulnerability

ZDI details CVE-2026-20147, an authenticated command injection in Cisco Identity Services Engine allowing remote code execution, rated CVSS 7.2.

ZDI-26-581 describes a command injection flaw in Cisco Identity Services Engine reachable through the invokeScript function. Remote attackers who authenticate can execute arbitrary code on affected installations. The issue is tracked as CVE-2026-20147 and carries a CVSS rating of 7.2. No exploitation activity is reported in the advisory.

ZDI Published Advisories · Aug 13, 2026VulnerabilityCVE-2026-20147

Mitsubishi Electric CNC Series (Update A)

CISA's updated ICS advisory details CVE-2025-2399, an out-of-bounds read in Mitsubishi Electric CNC series that lets a remote attacker cause a denial-of-service condition.

CISA released Update A of ICS advisory ICSA-26-078-05 covering Mitsubishi Electric CNC series controllers. The vulnerability CVE-2025-2399 is an out-of-bounds read that a remote attacker can exploit to trigger a denial-of-service condition. Affected products include M800VW, M800VS, M80V, M80VW, M800W, M800S and M80 series controllers up to specified firmware revisions. No exploitation is reported in the advisory.

CISA Advisories · 19d agoAdvisoryCVE-2025-2399

[Control Systems] Inductive Automation security advisory (AV26-892)

Canada's Cyber Centre relayed a CISA ICS advisory for an Inductive Automation Ignition vulnerability affecting versions up to 8.1.53.

The Canadian Centre for Cyber Security published control systems advisory AV26-892, noting that as of September 4, 2026, Inductive Automation is affected by a vulnerability in Ignition versions prior to or equal to 8.1.53. The advisory references CISA's ICS advisory (ICSA-26-246-06) and its CSAF file, and encourages users and administrators to review the linked resources and apply necessary updates as they become available. Ignition is a widely deployed industrial automation platform, so affected OT operators should patch promptly.

Canadian Centre for Cyber Security · 7d agoAdvisory

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 12d agoAdvisoryCVE-2026-77393

Mitsubishi Electric Multiple FA Products (Update D)

CISA warns Mitsubishi Electric CC-Link IE TSN remote I/O modules are vulnerable to denial-of-service via crafted UDP packets (CVE-2025-3511).

CISA published Update D of advisory ICSA-25-128-03 covering Mitsubishi Electric factory automation products. Affected products include CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, and NZ2GN2S1-32DT at firmware version 09 or earlier (CVE-2025-3511). A remote attacker can send a specially crafted UDP packet to cause denial-of-service conditions, timeout errors, or communication delays on the affected products.

CISA Advisories · 19d agoAdvisoryCVE-2025-3511

Citrix urges customers to fix critical NetScaler authentication bypass (CVE-2026-19490)

Citrix patched a critical authentication bypass, CVE-2026-19490, in NetScaler Gateway and NetScaler ADC, urging customers to upgrade immediately.

Citrix has patched two flaws in NetScaler ADC and NetScaler Gateway. CVE-2026-19490 is a critical authentication bypass (CVSS v4.0 9.3) that works when the appliance is configured as an SSL VPN, ICA Proxy, CVPN, RDP Proxy Gateway or AAA virtual server, with additional conditions depending on firmware and SAML configuration. A second flaw, CVE-2026-19489 (CVSS 8.8), is a memory overflow that can cause denial of service when SIP ALG is enabled on LSN setups. Rapid7 had not observed exploitation as of August 19, 2026, but urged emergency patching; a signature-based mitigation is available via NetScaler Console.

Water sector example added to the NCSC’s Secure connectivity principles

NCSC UK adds a water sector example to its Secure Connectivity Principles, the first ICS community-authored content on its site.

The UK NCSC has added a water sector example to its Secure Connectivity Principles guidance. It is the first content authored by the Industrial Control System Community of Interest to appear on ncsc.gov.uk. The guidance helps ICS operators apply secure connectivity practices.

NCSC UK · Aug 11, 2026Advisory

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Frequently asked questions about the active threat to Siemens S7 Series PLCs

US government agencies warn that unattributed actors using AI-generated exploit scripts are targeting internet-exposed Siemens S7 PLCs in critical infrastructure.

A joint advisory from multiple U.S. government agencies warns that threat actors are exploiting known weaknesses and unnecessary internet exposure of Siemens S7 Series PLCs for reconnaissance and possible pre-positioning for future disruptive attacks. The attackers use AI to generate and refine exploit scripts faster than manual development would allow, lowering the technical bar for ICS attacks. There is no single patch, so defenders must reduce internet exposure and improve monitoring of ICS environments.

Tenable Blog · 26d agoExploit / PoC in the wild

[webapps] Ghost_CMS 6.19.0 - Remote Code Execution

A public proof-of-concept demonstrates remote code execution in Ghost CMS 6.19.0, the widely deployed open-source publishing platform.

Exploit-DB lists a remote code execution proof of concept affecting Ghost CMS version 6.19.0. Ghost is a popular open-source platform used by publishers and blogs worldwide. The listing does not cite a CVE id or report in-the-wild exploitation.

Exploit-DB · 14d agoExploit / PoC1

Secure Access Service Edge (SASE) Archives

Palo Alto Unit 42 archive page describing Secure Access Service Edge (SASE), a cloud architecture unifying SD-WAN with SWG, CASB, FWaaS and ZTNA services.

Category archive page defining SASE as a cloud-native architecture that converges SD-WAN with security functions such as SWG, CASB, FWaaS and ZTNA into one cloud service. It frames SASE as a shift from separate networking and security disciplines to unified, cloud-delivered security and connectivity. The page contains no news, incident, vulnerability or research findings.

Palo Alto Unit 42 · 29d agoIndustry

ICS Operators Warned of AI-Driven Attacks on Siemens PLCs

A US government advisory warns attackers are using AI-generated exploitation scripts against internet-exposed Siemens S7 Series PLCs.

A US government advisory warns ICS operators that attackers are targeting exposed Siemens S7 Series PLCs using AI-generated exploitation scripts. The use of AI to automate exploit development and delivery marks an escalation in threats to industrial control systems. Operators of exposed PLCs are warned to harden their environments as AI-assisted tooling lowers the barrier for adversaries.

Infosecurity Magazine · 27d agoExploit / PoC in the wild

Rockwell Automation OTTO Fleet Manager

CISA warns Rockwell Automation OTTO Fleet Manager (CVE-2026-75112, CVSS 6.8) uses insufficiently costly password hashing, easing offline brute-force attacks.

CISA published ICS advisory ICSA-26-239-03 for Rockwell Automation OTTO Fleet Manager versions 2.36.2 and earlier (CVE-2026-75112, CVSS v3 6.8). The flaw involves use of a password hash with insufficient computational effort, reducing the cost for an attacker to perform offline brute-force attacks against stored password hashes. Deployments span critical manufacturing and transportation systems sectors worldwide, with company headquarters in the United States.

CISA Advisories · 19d agoAdvisoryCVE-2026-75112

[webapps] C-MOR 6.0104 - Cross-Site Scripting (XSS)

A proof-of-concept cross-site scripting exploit for C-MOR video surveillance software 6.0104 appeared on Exploit-DB.

Exploit-DB published a proof-of-concept cross-site scripting (XSS) exploit against C-MOR 6.0104, an IP video surveillance platform. The listing demonstrates script injection in the web interface, but the provided text contains no CVE identifier or indication of active exploitation. Successful XSS against the surveillance console could enable session hijacking or manipulation of the monitoring interface.

Exploit-DB · 16d agoExploit / PoC1

CVE-2026-19490: Critical Vulnerability Affecting Citrix NetScaler ADC and NetScaler Gateway

CVE-2026-19490 is a critical unauthenticated authentication bypass in Citrix NetScaler ADC and Gateway, remotely exploitable without user interaction.

An advisory published August 19, 2026 describes CVE-2026-19490, a critical authentication bypass affecting Citrix NetScaler ADC and NetScaler Gateway. The flaw carries a CVSS v4.0 base score of 9.3 and is remotely exploitable by unauthenticated attackers over the network without user interaction or elevated privileges. NetScaler ADC and Gateway are widely deployed enterprise products positioned at or near the network perimeter, providing load balancing, SSL/TLS offloading, and secure remote access. The text does not state whether exploitation has been observed in the wild.

Rapid7 Blog · 27d agoVulnerabilityCVE-2026-194901

Applied Systems Engineering ASE2000 V2 Communications Test Set

CISA warns ASE2000 V2 test sets allow arbitrary file read/write, outbound request abuse, and TLS peer impersonation; version 2.38 fixes both vulnerabilities.

CISA published ICS advisory ICSA-26-239-04 for Applied Systems Engineering (Kalkitech) ASE2000 V2 Communications Test Set versions 2.25 through 2.37. Exploitation could allow reading or writing arbitrary local files, forcing outbound network requests, or intercepting the TLS connection to impersonate the trusted peer and read or modify protected communications. Vendor ASE/Kalkitech provides upgraded version 2.38, which also updates the bundled log4net library, fixing both vulnerabilities; customers are advised to upgrade.

CISA Advisories · 19d agoAdvisory

Cisco Packaged Contact Center Enterprise and Cisco Unified Contact Center Enterprise Server-Side Request Forgery Vulnerability

Cisco patched an authenticated SSRF flaw in Packaged CCE and Unified CCE that lets credentialed users send arbitrary network requests from affected devices.

A server-side request forgery vulnerability caused by improper input validation of specific HTTP requests affects Cisco Packaged Contact Center Enterprise and Cisco Unified Contact Center Enterprise. An authenticated, remote attacker with valid user credentials can send crafted HTTP requests to make the device issue arbitrary network requests. Cisco has released software updates; no exploitation is reported in the advisory.

Cisco Security Advisories · 27d agoAdvisory

ZDI-26-579: Cisco Identity Services Engine zipFiles Directory Traversal Remote Code Execution Vulnerability

ZDI disclosed an authenticated directory traversal flaw (CVE-2026-20181) in Cisco Identity Services Engine allowing remote code execution, CVSS 7.2.

The Zero Day Initiative published ZDI-26-579 describing a directory traversal in the zipFiles functionality of Cisco Identity Services Engine. Authenticated remote attackers can execute arbitrary code on affected installations. ZDI assigned a CVSS score of 7.2 and the identifier CVE-2026-20181.

ZDI Published Advisories · Aug 13, 2026VulnerabilityCVE-2026-20181

Cisco Integrated Management Controller Argument Injection Vulnerabilities

Cisco patched multiple argument-injection vulnerabilities in Cisco IMC's web management interface allowing authenticated attackers root command execution.

Cisco published an advisory covering multiple argument injection vulnerabilities in the web-based management interface of Cisco Integrated Management Controller (IMC). An authenticated, remote attacker could exploit them to execute arbitrary commands on the underlying operating system and elevate privileges to root. Cisco released software updates and states there are no workarounds; the advisory carries a High Security Impact Rating.

Cisco Security Advisories · 14h agoAdvisory

Cisco confirms CVE-2026-20079 Secure FMC flaw exploited in attacks

Cisco confirmed active exploitation of CVE-2026-20079, a CVSS 10.0 authentication bypass enabling unauthenticated root command execution in Secure FMC; CISA added it to KEV.

Cisco confirmed in August 2026 that CVE-2026-20079 (CVSS 10.0), an unauthenticated authentication bypass in Secure Firewall Management Center, is being actively exploited, allowing remote attackers to execute scripts and commands as root via crafted HTTP requests to the web interface. CISA added the flaw to its Known Exploited Vulnerabilities catalog, ordering federal civilian agencies to patch by September 12, 2026. Shared IOCs, identical hot fixes, and a July 23 log entry suggest CVE-2026-20079 was used alongside the separately exploited static-credential flaw CVE-2026-20316 in the same attacks. Cisco released patches and cloud fixes, warns hot fixes do not remediate already-compromised devices, and says there are no workarounds.

BleepingComputerupdated · 2d agofirst · 6d agoExploit / PoC in the wild 13 sourcesCVE-2026-20079CVE-2026-20316

CVE-2026-34908: Ubiquiti Networks UniFi OS Server access control ...

CVE-2026-34908, a CVSS 10.0 access-control bypass in Ubiquiti UniFi OS, was added to CISA's KEV catalog amid reported active exploitation.

CISA added CVE-2026-34908 to the Known Exploited Vulnerabilities catalog on June 23, 2026, with remediation due June 26 under BOD 26-04 guidance. The CVSS 10.0 improper access control flaw (CWE-284) in Ubiquiti UniFi OS allows unauthorized system changes without authentication. Multiple news reports referenced by the page describe the max-severity UniFi flaws being exploited in attacks, and an official patch is available.

Langflow Remote Code Execution Vulnerability Exploited in Attacks (CVE-2026-0768)

Critical CVSS 9.8 RCE CVE-2026-0768 in Langflow is under active exploitation, with attackers probing for credentials and secrets.

CVE-2026-0768, a critical (CVSS 9.8) remote code execution flaw in Langflow's code validator, lets attackers execute Python code with root privileges via the validate endpoint's code parameter. VulnCheck honeypots in the UK detected Russian-origin exploitation performing reconnaissance and credential harvesting, querying environment variables like LANGFLOW_SUPERUSER and AWS keys and reading Langflow's secret key. Versions before 1.4.2 are affected; no vendor advisory or public PoC was available at reporting time.

Qualys ThreatPROTECT · 13d agoExploit / PoC in the wildCVE-2026-0768CVE-2026-33017CVE-2026-5027+1 CVEs1

AWS Systems Manager Agent Vulnerability Allows Attackers to Bypass Port-Forwarding Restrictions

Critical SSRF flaw in AWS SSM Agent (CVE-2026-89049) lets authenticated users bypass link-local denylists and reach EC2 Instance Metadata Service for IAM credentials.

CVE-2026-89049 (Critical, CVSS v3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H) affects Amazon SSM Agent versions earlier than 3.3.4851.0, with the fix shipping in 3.3.4851.0. The remote-host port-forwarding feature's denylist for link-local addresses can be bypassed because equivalent address representations are not validated, enabling SSRF to restricted endpoints such as the EC2 Instance Metadata Service at 169.254.169.254. An attacker with authenticated AWS access and ssm:StartSession permission could retrieve instance profile IAM credentials and pivot to S3, Secrets Manager, Lambda, or other cloud resources depending on role permissions.

Privilege escalation from IIS AppPool to NT Authority/SYSTEM

A write-up demonstrates privilege escalation from an IIS AppPool identity to NT AUTHORITY/SYSTEM via the AD CS RPC endpoint.

A technical write-up details a Windows privilege escalation path that moves an IIS application pool identity to NT AUTHORITY/SYSTEM by abusing the Active Directory Certificate Services RPC endpoint. The technique chains the restricted IIS AppPool service context with AD CS access to reach SYSTEM on the host. The post is relevant for defenders mapping privilege escalation paths on Windows web servers.

Lobsters · security · 15d agoResearch