FrostyGoop’s Zoom-In: A Closer Look into the Malware Artifacts, Behaviors and Network Communications
Unit 42 dissects FrostyGoop OT malware, which sent Modbus TCP commands to disrupt heating for 600+ apartment buildings in Ukraine.
Palo Alto Unit 42 analyzed new FrostyGoop/BUSTLEBERM samples, the ninth known ICS-centric malware, first used against a Ukrainian municipal energy company by sending Modbus TCP commands to ENCO control devices. The attack caused a two-day heating outage affecting over 600 apartment buildings during sub-zero temperatures. The Go-compiled malware accepts Modbus register operations and timing parameters via command-line arguments or a JSON configuration file, uses an obscure open-source Modbus library, and checks the Windows BeingDebugged flag to evade debuggers. Unit 42 telemetry recorded over 1 million Modbus TCP devices exposed to the internet between September and October 2024.
AI Tool Identifies BOLA Vulnerabilities in Easy!Appointments
Unit 42's AI-powered tool found 15 BOLA vulnerabilities in Easy!Appointments, rated up to CVSS 9.9, letting low-privileged users escalate privileges; fixed in 1.5.0.
Unit 42's automated BOLA detection tool, built on generative AI, uncovered 15 broken object-level authorization flaws in the open-source scheduling application Easy!Appointments, tracked as CVE-2023-3285 through CVE-2023-3290 and CVE-2023-38047 through CVE-2023-38055. Nine flaws scored CVSS 9.9, letting logged-in customers view or manipulate appointments and accounts of providers and admins, including creating admin users for privilege escalation. The maintainers patched all issues in version 1.5.0. The same tool previously found a BOLA in Grafana (CVE-2024-1313).
Identifying a BOLA Vulnerability in Harbor, a Cloud
Unit 42 found a BOLA flaw, CVE-2024-22278 (CVSS 6.4), letting Maintainers improperly alter Harbor project metadata; fixed in versions 2.9.5, 2.10.3, and 2.11.0.
Unit 42 researchers identified a broken object-level authorization flaw, CVE-2024-22278, in Harbor, a CNCF-graduated cloud-native container registry with 1.8 million downloads. The flaw (CVSS 6.4) lets users with the Maintainer role create, update, and delete project metadata, actions reserved for ProjectAdmin, risking data exposure, integrity compromise, and circumvention of vulnerability scanning. Harbor patched the issue in versions 2.9.5, 2.10.3, and 2.11.0. The finding came from Unit 42's automated BOLA detection tool built on generative AI.
Multiple Vulnerabilities Discovered in a SCADA System
Unit 42 details five vulnerabilities (CVSS 7.0-7.8) in ICONICS Suite SCADA software enabling privilege escalation and DoS.
Unit 42 discovered five vulnerabilities (CVE-2024-1182, CVE-2024-7587, CVE-2024-8299, CVE-2024-8300, CVE-2024-9852) in ICONICS Suite versions 10.97.2 and earlier for Windows during a 2024 security assessment. The flaws, rated CVSS 7.0-7.8, allow DLL hijacking, privilege escalation, information disclosure, denial-of-service and potentially full system compromise. ICONICS Suite is a SCADA solution with hundreds of thousands of installations in over 100 countries, widely used in critical infrastructure, and several dozen servers are internet-exposed per Unit 42 telemetry. ICONICS released patches and advisories with workarounds in 2024.
A Deep Dive Into Attempted Exploitation of CVE-2023
Mirai-like botnet scans exploit TP-Link EOL router flaw CVE-2023-33538 after CISA KEV addition, though observed exploit code is flawed.
Unit 42 observed large-scale automated scans attempting to exploit CVE-2023-33538 in end-of-life TP-Link TL-WR940N, TL-WR740N and TL-WR841N routers after CISA added the flaw to its KEV catalog in June 2025. HTTP GET requests inject commands via the ssid1 parameter at the /userRpm/WlanNetworkRpm endpoint to download and execute an arm7 ELF binary, a Mirai variant related to the Condi IoT botnet. Firmware emulation and reverse engineering showed the observed exploits are flawed and would fail, but the underlying vulnerability is real and successful exploitation requires authentication to the router's web interface. TP-Link confirmed the devices are end-of-life with no patches available and recommends replacing units and eliminating default credentials.