ZeroHour

Search: “monitorability”

3,197 stories

Tycon Systems TPDIN-Monitor-WEB3

CISA reports three flaws (hard-coded credentials, CSRF, missing authorization) in Tycon TPDIN-Monitor-WEB3 <=2.2.9 enabling MitM, credential theft, or device resets.

CISA published ICSA-26-246-08 for Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior, covering CVE-2026-77847 (use of hard-coded credentials, CWE-798), CVE-2026-82712 (CSRF, CWE-352), and CVE-2026-82684 (missing authorization, CWE-862). Exploitation could enable man-in-the-middle attacks, factory resets, credential wiping, or extraction of system credentials, configurations, and flash contents; the CSRF issue scores CVSS 8.8. No public exploitation has been reported; CISA recommends isolating devices from business networks.

AVEVA Pipeline Integrity Monitor

CISA advisory details four flaws in AVEVA Pipeline Integrity Monitor <=2025_SP1_P1, allowing information disclosure, weak-hash admin elevation, and cross-site scripting.

CISA published ICSA-26-253-01 covering AVEVA Pipeline Integrity Monitor versions <=2025_SP1_P1_build_7.1.9580.8513. CVE-2026-81821 (hard-coded cryptographic key, CWE-321) lets a user with read access decrypt PIMBoards project files, and CVE-2026-81822 (CWE-327) allows brute-forcing weak password hashes to elevate to PIMBoards administrator; both score 8.4 HIGH (CVSS v3.1). CVE-2026-81823 (CWE-862) permits unauthenticated read operations, and CVE-2026-81824 (CWE-79) enables arbitrary JavaScript execution via socially engineered links. CISA reports no known public exploitation and recommends limiting network exposure of control system devices.

Multiple Vulnerabilities Discovered in a SCADA System

Unit 42 details five vulnerabilities (CVSS 7.0-7.8) in ICONICS Suite SCADA software enabling privilege escalation and DoS.

Unit 42 discovered five vulnerabilities (CVE-2024-1182, CVE-2024-7587, CVE-2024-8299, CVE-2024-8300, CVE-2024-9852) in ICONICS Suite versions 10.97.2 and earlier for Windows during a 2024 security assessment. The flaws, rated CVSS 7.0-7.8, allow DLL hijacking, privilege escalation, information disclosure, denial-of-service and potentially full system compromise. ICONICS Suite is a SCADA solution with hundreds of thousands of installations in over 100 countries, widely used in critical infrastructure, and several dozen servers are internet-exposed per Unit 42 telemetry. ICONICS released patches and advisories with workarounds in 2024.

[0day-rubbish] OP5 Monitor 9.20 Command injection surviving the CVE-2025-34115 patch (OPT-IN fix ineffective) (8.8)

OP5 Monitor 9.20 remains vulnerable to CVSS 8.8 command injection because the CVE-2025-34115 fix is opt-in and ineffective.

0day Rubbish Research Team disclosed a command injection (CWE-78) in OP5 Monitor 9.20 that survives the existing CVE-2025-34115 patch, which is opt-in and described as ineffective. The issue scores CVSS 8.8 (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Administrators who previously applied the vendor fix may still be exposed.