Skip to content
NewA calmer, faster ZeroHour

CVE-2026-89201

Authenticated SQL injection in Siemens RUGGEDCOM CROSSBOW

CVSS 4.0
7.7 high
EPSS
—
Published
·
Modified
Analyze CVE-2026-89201 with Vani AIImpact, affected versions, exploitation status, mitigations and detection

Siemens RUGGEDCOM CROSSBOW before V6.0 does not properly validate or sanitize device group or facility names used in the Bulk Export workflow, allowing SQL injection (CWE-89). An authenticated attacker who already has the required privileges can send crafted names over the network and run arbitrary SQL against the underlying database. Successful exploitation can fully compromise confidentiality, integrity, and availability of that database (CVSS 4.0 base 7.7), though attack complexity is rated high and privileges are required. All CROSSBOW releases earlier than V6.0 are affected. It is not listed in CISA KEV, and no public proof-of-concept is known.

What to do: Upgrade RUGGEDCOM CROSSBOW to V6.0 or later. Until then, limit Bulk Export and device-group or facility-name privileges to trusted administrators, and keep the management interface off untrusted networks.

ProductAffected
Siemens RUGGEDCOM CROSSBOWAll versions < V6.0
Estimated exposure
nicheNo basis for an estimate.

Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.

Description · NVD

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.

Weakness
CWE-89
Vector
CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

In the news

1 story