RUGGEDCOM APE1808 inherits Nozomi Guardian and CMC flaws

Original title: Siemens RUGGEDCOM APE1808 Devices

CISA Advisoriesby CISA ()6 min read
AI summary · x-ai/grok-4.7Summaries by Vani AI

All listed APE1808 versions are affected; the highest detailed score is 7.5 for unvalidated Smart Polling connections.

Siemens says RUGGEDCOM APE1808 devices running Nozomi Guardian/CMC are affected by vulnerabilities Nozomi Networks disclosed. Issues include dashboard template injection, weak Credentials Manager authorization, missing host validation in Smart Polling, Smart Polling access-control bypass, and a login CSRF whose description is cut off. Every listed version is known affected. Siemens tells customers to contact support for patch information.

Unconfirmed: The CSRF write-up is truncated, and no fixed version is named.

Key facts
  • CVE-2026-33389 scores 7.5 and can let a MITM capture polling credentials.
  • CVE-2026-33388 scores 7.4; limited users can edit or delete credential entries.
  • CVE-2026-33387 scores 4.6 and CVE-2026-33391 scores 5.4.
  • CVE-2026-33920 is a login CSRF; the excerpt ends mid-description.
Security assessment · AI, from the article

Impact: Credential interception, data changes, or disrupted monitoring

ProductAffected
Siemens RUGGEDCOM APE1808 with Nozomi Guardian/CMCall versions
What to do
  1. 1.Contact Siemens customer support for patch and update information.
Analyze this story with Vani AIImpact, who is affected and what defenders should do, in a new chat

Vulnerabilities mentioned

All
CVEVulnerabilityCVSSEPSSSignalsPublished
CVE-2026-33387
Dashboards functionality due to improper validation of an input parameter: An authenticated user with the required privileges can define a dashboard containing a malicious payload, or a victim can be…
5.1<1%
CVE-2026-33388
An access control vulnerability was discovered in the Credentials Manager functionality due to insufficient validation of user privileges
6.4<1%
CVE-2026-33389
An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target…
5.3<1%
CVE-2026-33391
An access control vulnerability was discovered in the Smart Polling configuration functionality due to insufficient validation of user privileges
5.3<1%
CVE-2026-33920
A cross-site request forgery vulnerability was discovered in the login functionality (both standard and SAML) due to missing validation of the anti-CSRF token
5.1<1%