Siemens Software Center
Siemens Software Center
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and…
Vulnerabilities mentionedAll →
- CVE-2026-1109368.4<1%DLL Search-Path Hijacking in Siemens Software Centerpublished · Siemens Software Center KEV
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2026-110936 | DLL Search-Path Hijacking in Siemens Software Center Siemens Software Center, in all versions, loads dynamic-link libraries from an uncontrolled search path (CWE-427). An authenticated local attacker who already has high privileges can place a crafted DLL in a directory the application searches, so the program loads that library. Successful exploitation runs arbitrary code with the privileges of Siemens Software Center and can fully compromise confidentiality, integrity, and availability on that system. The issue is local only: it requires high privileges, no user interaction, and does not extend impact to other systems under the published CVSS 4.0 score of 8.4. It is not listed in CISA KEV, and no public proof-of-concept is known. |
Full article724 words · extracted from cisa.gov · click to collapse
Summary
The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it.
The following versions of Siemens Software Center are affected:
- Siemens Software Center vers:intdot/<4.0.9.8 (CVE-2026-110936)
| CVSS | Vendor | Equipment |
|---|---|---|
| v3 6.7 | Siemens | Siemens Software Center |
| 1 Vulnerability |
|---|
| Uncontrolled Search Path Element |
Background
- Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-110936
The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application.
1 Affected Product
Siemens Software Center < V4.0.9.8
Product Status: known_affected
Remediations
Vendor fix
Update to V4.0.9.8 or later version (All existing versions of SSC will be auto updated on next startup. The latest version can also be downloaded in the respective link)
Additional Metrics
Relevant CWE: CWE-427 Uncontrolled Search Path Element
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 6.7 | MEDIUM | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
Acknowledgments
- Siemens ProductCERT reported this vulnerability to CISA.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.
- Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
- Locate control system networks and remote devices behind firewalls and isolating them from business networks.
- When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens ProductCERT SSA-580366 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
- Initial Release Date: 2026-10-15
| Date | Revision | Summary |
|---|---|---|
| 2026-10-15 | 1 | Publication Date |
| 2026-10-17 | 2 | Added remediation for Siemens Software Center |
| 2026-10-19 | 3 | Added reference to blog post about active exploitation of the vulnerability |
| 2026-10-22 | 4 | Initial CISA Republication of Siemens ProductCERT SSA-580366 advisory |