vCenter Flaw Exploited Just Five Days After Disclosure
Attackers began exploiting critical vCenter flaw CVE-2026-59310 five days after Broadcom's disclosure, putting enterprise VMware deployments at risk.
Attackers exploited a critical-severity flaw in VMware vCenter, tracked as CVE-2026-59310, just five days after Broadcom disclosed it. vCenter is the management platform for large enterprise VMware virtualization estates, so active exploitation exposes a broad installed base. Defenders running vCenter should prioritize applying Broadcom's patch.
- Critical vCenter flaw CVE-2026-59310 is being actively exploited
- Exploitation began five days after Broadcom's disclosure
- vCenter manages enterprise VMware virtualization environments at scale
- Rapid exploitation shows short patch windows for virtualization infrastructure
Vulnerabilities mentionedAll →
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2026-59310 | Unauthenticated Path Traversal RCE in Broadcom VMware vCenter Server Syslog CVE-2026-59310 is a directory traversal (CWE-22) vulnerability in the Syslog server component of VMware vCenter Server, rated critical at CVSS 9.8. It can be triggered over the network without authentication or user interaction, allowing a malicious actor with network access to vCenter to achieve arbitrary code execution. An attacker who exploits it gains code execution on the vCenter appliance, and reported campaigns show it has been used to establish persistent remote access and, by a suspected China-nexus actor, to deploy Babuk ransomware. Any organization running an affected version of vCenter Server is exposed, especially where the management interface is reachable from the internet; the available data does not specify affected version ranges. Exploitation is confirmed in the wild: CISA added the flaw to its Known Exploited Vulnerabilities catalog on 2026-08-18, it was reportedly exploited just five days after disclosure, and EPSS estimates a 45.9% probability of exploitation within 30 days (99th percentile). Do: Upgrade vCenter Server to the patched release identified in Broadcom's advisory (no specific version ranges are provided in this data) and prioritize any vCenter that is internet-facing, in line with CISA KEV and BOD 26-04 requirements for federal agencies. Until patched, restrict access to the vCenter management interface to trusted networks and verify whether the vCenter Syslog server is enabled. Hunt for compromise indicators, including unexplained remote-access persistence and Babuk ransomware artifacts, given the documented China-nexus exploitation. | 9.8 | 46% | KEV ransomware |
| largeApproximately 50,000-100,000 internet-exposed vCenter Server instances, with total deployments (including internal-only) likely in the hundreds of thousands |
Attackers exploited a critical-severity vCenter flaw five days after Broadcom disclosed it
This source does not provide full text. Read it at infosecurity-magazine.com.