Several New Critical Flaws Affect CODESYS Industrial Automation Software

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2020-15782
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl.

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.

NVD description · AI analysis pending
9.85%
  • siemens simatic driver controller firmware
  • siemens s7-1200 cpu firmware
  • siemens s7-1500 cpu firmware
  • +1 more
CVE-2021-22779
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), Eco

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

NVD description · AI analysis pending
9.11%
  • schneider-electric ecostruxure control expert
  • schneider-electric ecostruxure process expert
  • schneider-electric remoteconnect
  • +1 more
CVE-2021-29238
CODESYS Automation Server before 1.16.0 allows cross-site request forgery (CSRF).

CODESYS Automation Server before 1.16.0 allows cross-site request forgery (CSRF).

NVD description · AI analysis pending
8.8<1%
  • codesys automation server
CVE-2021-29240
The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODES

The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.

NVD description · AI analysis pending
7.8<1% PoC
  • codesys development system
CVE-2021-29241
CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).

CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS).

NVD description · AI analysis pending
7.51%
  • codesys control for beaglebone sl
  • codesys control for empc-a\/imx6 sl
  • codesys control for iot2000 sl
  • +1 more
CVE-2021-34569
+3 in the same advisory: …34566 …34567 …34568
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write mem

In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.

NVD description · AI analysis pending
9.8
group max
<1%
  • wago 750-8100 firmware
  • wago 750-8101 firmware
  • wago 750-8101\/025-000 firmware
  • +1 more
Full article916 words · extracted from thehackernews.com · click to collapse

Ravie LakshmananJul 21, 2021

Cybersecurity researchers on Wednesday disclosed multiple security vulnerabilities impacting CODESYS automation software and the WAGO programmable logic controller (PLC) platform that could be remotely exploited to take control of a company's cloud operational technology (OT) infrastructure.

The flaws can be turned "into innovative attacks that could put threat actors in position to remotely control a company's cloud OT implementation, and threaten any industrial process managed from the cloud," the New York-headquartered industrial security company Claroty said in a report shared with The Hacker News, adding they "can be used to target a cloud-based management console from a compromised field device, or take over a company's cloud and attack PLCs and other devices to disrupt operations."

CODESYS is a development environment for programming controller applications, enabling easy configuration of PLCs in industrial control systems. WAGO PFC100/200 is a series of PLCs that make use of the CODESYS platform for programming and configuring the controllers.

The list of seven vulnerabilities is listed below -

  • CVE-2021-29238 (CVSS score: 8.0) - Cross-site request forgery in CODESYS Automation Server
  • CVE-2021-29240 (CVSS score: 7.8) - Insufficient Verification of Data Authenticity in CODESYS Package Manager
  • CVE-2021-29241 (CVSS score: 7.5) - Null pointer dereference in CODESYS V3 products containing the CmpGateway component
  • CVE-2021-34569 (CVSS score: 10.0) - WAGO PFC diagnostic tools – Out-of-bounds write
  • CVE-2021-34566 (CVSS score: 9.1) - WAGO PFC iocheckd service "I/O-Check" – Shared memory buffer overflow
  • CVE-2021-34567 (CVSS score: 8.2) - WAGO PFC iocheckd service "I/O-Check" – Out-of-bounds read
  • CVE-2021-34568 (CVSS score: 7.5) - WAGO PFC iocheckd service "I/O-Check" – Allocation of resources without limits

Successful exploitation of the flaws could enable the installation of malicious CODESYS packages, result in a denial-of-service (DoS) condition, or lead to privilege escalation via execution of malicious JavaScript code, and worse, manipulation or complete disruption of the device.

In the wild, this could play out in one of two ways: "bottom-up" or "top-down." The twin approaches mimic the paths an adversary is likely to take to either control a PLC endpoint in order to eventually compromise the cloud-based management console, or the reverse, commandeer the cloud in order to manipulate all networked field devices.

In a complex "bottom-up" exploit chain devised by Claroty, a mix of CVE-2021-34566, CVE-2021-34567, and CVE-2021-29238 were exploited to obtain remote code execution on the WAGO PLC, only to gain access to the CODESYS WebVisu human-machine interface and stage a cross-site request forgery (CSRF) attack to seize control of the CODESYS automation server instance.

"An attacker that obtains access to a PLC managed by the Automation Server Cloud can modify the 'webvisu.js' file and append JavaScript code to the end of the file that will send a malicious request to the cloud server on behalf of the logged in user," Claroty senior researcher Uri Katz, who discovered and reported the flaws, explained.

"When a cloud user views the WebVisu page, the modified JavaScript will exploit the lack of CSRF token and run in the context of the user viewing it; the request will include the CAS cookie. Attackers can use this to POST to '/api/db/User' with a new administrator user, giving them full access to the CODESYS cloud platform," Katz added.

An alternate "top-down" attack scenario, on the other hand, involves compromising the CODESYS engineering station by deploying a malicious package (CVE-2021-29240) that's designed to leak the cloud credentials associated with an operator account, and subsequently using it to tamper with the programmed logic and gain unfettered access to all the connected PLCs.

"Organizations moving forward with cloud-based management of OT and ICS devices must be aware of the inherent risks, and increased threats from attackers keen on targeting industrial enterprises with extortion-based attacks—including ransomware—and more sophisticated attacks that can cause physical damage," Katz said.

The disclosures mark the second time critical flaws that have been uncovered in CODESYS and WAGO PLCs in as many months. In June, researchers from Positive Technologies revealed ten critical vulnerabilities in the software's web server and runtime system components that could be abused to gain remote code execution on the PLCs.

The development also comes a week after IoT security firm Armis disclosed a critical authentication bypass vulnerability affecting Schneider Electric Modicon PLCs — dubbed "ModiPwn" (CVE-2021-22779) — that could be exploited to allow full control over the PLC, including overwriting critical memory regions, leaking sensitive memory content, or invoking internal functions.

In a related report published earlier this May, Claroty made public a memory protection bypass vulnerability in Siemens SIMATIC S7-1200 and S7-1500 PLCs (CVE-2020-15782) that could be leveraged by a malicious actor to remotely gain access to protected areas of the memory and achieve unrestricted and undetected code execution.

The revelations also coincide with a joint cybersecurity advisory released by the U.S. Cybersecurity and Infrastructure Security Agency (CISA) and the Federal Bureau of Investigation (FBI) documenting a historical spear-phishing and intrusion campaign conducted by state-sponsored Chinese actors from December 2011 to 2013, targeting 23 oil and natural gas (ONG) pipeline operators in the country.

"CISA and the FBI assess that these actors were specifically targeting U.S. pipeline infrastructure for the purpose of holding U.S. pipeline infrastructure at risk," the agencies said. "Additionally, CISA and the FBI assess that this activity was ultimately intended to help China develop cyberattack capabilities against U.S. pipelines to physically damage pipelines or disrupt pipeline operations."

Found this article interesting? Follow us on Google News, Twitter and LinkedIn to read more exclusive content we post.

Text extracted automatically; images, tables and formatting may be missing. Original: https://thehackernews.com/2021/07/several-new-critical-flaws-affect.html