CVE-2021-22681
KEVmassAuthentication Bypass in Rockwell Automation Studio 5000 Logix Designer and Logix PLCs
CISA: Rockwell Multiple Products Insufficient Protected Credentials Vulnerability
Rockwell Automation's Studio 5000 Logix Designer (versions 21 and later) and RSLogix 5000 (versions 16 through 20) use a shared key to verify that they are communicating with genuine Allen-Bradley Logix controllers, and an unauthenticated remote attacker can bypass this verification mechanism (CWE-522, insufficient protection of credentials). The attack requires only network access to the affected software or controllers - no credentials, no user interaction, and no special conditions (CVSS 3.1: 9.8). By bypassing the verification, an attacker can authenticate to CompactLogix, ControlLogix, DriveLogix, Compact GuardLogix, GuardLogix and SoftLogix controllers and interact with the PLCs, potentially tampering with industrial processes. Any deployment running the affected engineering software versions with the listed Logix controller families is in scope, which spans a very large share of Rockwell's installed base. CISA added this flaw to its Known Exploited Vulnerabilities catalog on 2026-03-05 (ransomware use unknown), and EPSS puts the 30-day exploitation probability at roughly 64%; no public proof-of-concept is known.
What to do: Apply mitigations per Rockwell's instructions - the vendor has advised disconnecting internet-facing connections, so remove internet exposure from affected controllers and engineering workstations and segment OT networks. Follow applicable CISA BOD 22-01 guidance, and inventory for Studio 5000 Logix Designer v21+ or RSLogix 5000 v16-20 used with the listed controllers; upgrade per vendor guidance or discontinue use if mitigations are unavailable.
| Rockwell Automation Studio 5000 Logix Designer | v21 and later |
| Rockwell Automation RSLogix 5000 | v16 through v20 |
| Rockwell Automation FactoryTalk Services Platform | — |
| Rockwell Automation CompactLogix controllers (1768, 1769, 5370, 5380, 5480) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
| Rockwell Automation ControlLogix controllers (5550, 5560, 5570, 5580) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
| Rockwell Automation DriveLogix controllers (5560, 5730, 1794-L34) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
| Rockwell Automation Compact GuardLogix controllers (5370, 5380) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
| Rockwell Automation GuardLogix controllers (5570, 5580) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
| Rockwell Automation SoftLogix controllers (5800) | firmware versions not specified; affected when used with RSLogix 5000 v16-20 or Studio 5000 Logix Designer v21+ |
Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
- Affected
- Rockwell Multiple Products
- Required action
- Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
- Due date
- Ransomware use
- Unknown
- Vendors
- rockwellautomation
- Products
- factorytalk services platform, rslogix 5000, studio 5000 logix designer
- Weakness
- CWE-522
- Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H