CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

  • CVE-2026-81861 affects all versions of seven SCADAPack RTU product lines
  • CWE-522 flaw could expose auth data and allow unauthorized RTU config access
  • CVSS 3.1 score 6.5 medium; deployed worldwide in energy and manufacturing

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2026-81861
Insufficiently Protected Credentials in Schneider Electric SCADAPack x70 RTUs

CVE-2026-81861 is an insufficiently protected credentials flaw (CWE-522) affecting Schneider Electric SCADAPack x70 remote telemetry units (RTUs), in which authentication information is not adequately safeguarded. Because the flaw is network-reachable (AV:N) but requires some user interaction (UI:A) and for the vulnerable condition to be present (AT:P), an attacker would most plausibly induce an operator or legitimate user to take an action that exposes or transmits authentication data. A successful attack yields high confidentiality impact on the vulnerable system: exposure of authentication information that can then be reused to gain unauthorized access to RTU functionality, potentially allowing an adversary to read or manipulate remote telemetry and control operations. Organizations running SCADAPack x70 units in SCADA/ICS environments — typically utilities, oil and gas pipeline operators, and water/wastewater facilities — are the affected population. The issue carries a CVSS v4.0 base score of 5.9 (medium), is not in the CISA KEV catalog, and no public proof-of-concept or observed exploitation is known at this time.

Do: Apply the Schneider Electric security notification and firmware/software updates for SCADAPack x70 as soon as the advisory specifies fixed builds, since exact patched versions are not listed in this data. Rotate all RTU and management-console credentials on the assumption they may have been exposed, and verify that x70 management/network interfaces are not reachable from untrusted networks (enforce OT segmentation, VPN, or allowlisting). Because user interaction is part of the attack chain, brief operators to treat unsolicited links, configuration files, or authentication prompts involving SCADAPack tooling with suspicion, and review authentication and access logs for anomalous RTU sessions.

5.9
  • Schneider Electric SCADAPack x70
nichelikely thousands of field-deployed RTUs (order of magnitude: low thousands to tens of thousands of units across utility/industrial sites)
Full article1,215 words · extracted from cisa.gov · click to collapse

View CSAF

Summary

Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality.

The following versions of Schneider Electric SCADAPack x70 Products are affected:

  • SCADAPack 47x vers:all/* (CVE-2026-81861)
  • SCADAPack 47xi vers:all/* (CVE-2026-81861)
  • SCADAPack 47xd vers:all/* (CVE-2026-81861)
  • SCADAPack 470R vers:all/* (CVE-2026-81861)
  • SCADAPack 57x vers:all/* (CVE-2026-81861)
  • SCADAPack 3xx vers:all/* (CVE-2026-81861)
  • SCADAPack 32 vers:all/* (CVE-2026-81861)
CVSS Vendor Equipment Vulnerabilities
v3 6.5 Schneider Electric Schneider Electric SCADAPack x70 Products Insufficiently Protected Credentials

Background

  • Critical Infrastructure Sectors: Critical Manufacturing, Energy
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: France

Vulnerabilities

Expand All +

CVE-2026-81861

There is an insufficiently protected credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.

View CVE Details


Affected Products

Schneider Electric SCADAPack x70 Products

Vendor:
Schneider Electric

Product Version:
SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R, SCADAPack 57x, SCADAPack 3xx, SCADAPack 32

Product Status:
known_affected

Relevant CWE: CWE-522 Insufficiently Protected Credentials


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Acknowledgments

  • Abhinav Agarwal reported this vulnerability to CISA.

General Security Recommendations

Schneider Electric strongly recommends the following industry cybersecurity best practices:

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. 
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. 
  • Place all controllers in locked cabinets and never leave them in the “Program” mode. 
  • Never connect programming software to any network other than the network intended for that device. 
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. 
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. 
  • Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. 
  • When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. 

For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.


For More Information

This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp


LEGAL DISCLAIMER

THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION


Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. 

Our mission is to be the trusted partner in Sustainability and Efficiency. 

We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. 

We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. 

www.se.com


Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. 

  • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. 
  • Locate control system networks and remote devices behind firewalls and isolate them from business networks. 
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.


Advisory Conversion Disclaimer

This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-251-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.

Revision History

  • Initial Release Date: 2026-09-08