ZeroHour

Search: “missing authentication”

5 stories in the last 3d

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Cisco BroadWorks CommPilot Application Software Authorization Bypass Vulnerability

Cisco patched a BroadWorks CommPilot authorization bypass letting low-privileged authenticated users alter device configurations via crafted HTTP requests.

A vulnerability in the web-based management interface of Cisco BroadWorks CommPilot Application Software is caused by missing authorization checks. An authenticated remote attacker with low privileges can send crafted HTTP requests to alter configurations on select pages. Cisco has released software updates and no workarounds are available.

Cisco Security Advisories · 10h agoAdvisory