CVE-2026-84400

Missing Authentication in CareCam CM2507 IP Camera Enables Remote Debugging Access

CVSS 4.0
2.3 low
EPSS
—
Published
·
Modified
Analyze CVE-2026-84400 with Vani AIImpact, affected versions, exploitation status, mitigations and detection

CVE-2026-84400 is a missing-authentication flaw (CWE-306) in the network maintenance mechanism of CareCam CM2507 IP cameras, which can be abused to activate a remote debugging service. To trigger it, an attacker must already be on the same local network as the camera and the device must be in a specific state; no privileges or user interaction are required. If successful, the attacker can make the debugging service remotely accessible, increasing the risk of unauthorized administrative access, although the CVSS 4.0 score is low (2.3), with no confidentiality impact and only a low integrity impact. Any deployment of the CM2507 camera, typically in consumer or small-site installations, is affected. No exploitation in the wild, public proof of concept, or KEV listing is known.

What to do: Check with CareCam for updated CM2507 firmware and apply it as soon as a fixed version is published (none is specified in the available data). In the meantime, keep these cameras on a segmented network or VLAN separated from untrusted clients and disable any remote-administration or P2P access features that are not needed. If the model is no longer receiving firmware updates, monitor for the camera unexpectedly exposing a debugging service or consider replacing the device.

ProductAffected
CareCam CM2507 IP camera—
Estimated exposure
moderate≈10,000–100,000 devices worldwide (estimate; no public install-base or scan data for this specific model) — No public install-base or internet-exposure scan data exists for the CM2507, so the estimate is based on typical sales volumes for a single consumer IP camera model line from a smaller brand; actual attacker reach is further limited…

Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.

Description · NVD

CareCam CM2507 IP cameras contain an insufficiently protected network maintenance mechanism that can activate a remote debugging service. An attacker on the same local network who satisfies certain device state conditions could make the service remotely accessible, increasing the risk of unauthorized administrative access.

Weakness
CWE-306
Vector
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

In the news