ZeroHour

Search: “recording”

25 stories

September 2026 Patch Tuesday: Record patch count, 2 zero-days, and a SigRed successor

Microsoft's September 2026 Patch Tuesday delivers a record patch count, fixing two exploited zero-days and a wormable DNS flaw dubbed a SigRed successor.

Microsoft's September 2026 Patch Tuesday sets another record patch count, fixing two vulnerabilities exploited as zero-days: CVE-2026-81963, a Windows Update Stack low-privilege-to-SYSTEM escalation reported by MSTIC, and CVE-2026-85880, a Windows Advanced Local Procedure Call escalation reported by Proofpoint. Zero Day Initiative's Dustin Childs urges priority on a cluster of 20 potentially wormable bugs including DNS RCE CVE-2026-69730, described as a spiritual successor to SigRed, plus Kerberos authentication bypass CVE-2026-69676 that could give any authenticated domain user RCE on domain controllers, and Exchange RCE CVE-2026-55007 via a malicious Visio attachment. All Windows fixes are bundled in cumulative updates, and experts stress prioritizing exploitable, reachable flaws over raw patch counts.

Help Net Security · 8d agoAdvisory in the wildCVE-2026-81963CVE-2026-85880CVE-2026-69730+4 CVEs

Microsoft September 2026 Patch Tuesday fixes 966 flaws, 2 zero-days

Microsoft's September 2026 Patch Tuesday fixes a record 966 flaws, including two Windows zero-days actively exploited to gain SYSTEM privileges.

Microsoft's September 2026 Patch Tuesday addresses a record 966 vulnerabilities, including 105 rated Critical, 81 of them remote code execution bugs. Two zero-days were actively exploited: a Windows Update Stack link-following flaw and a Windows ALPC heap-based buffer overflow, both allowing local elevation to SYSTEM privileges. The ALPC flaw was reported by Volexity and Proofpoint researchers, while the Update Stack flaw was credited to Romain Deperne and the Microsoft Threat Intelligence Centre. Microsoft shared no details on how the flaws were exploited in attacks.

BleepingComputer · 8d agoAdvisory in the wildCVE-2026-69805CVE-2026-58649CVE-2026-69806+27 CVEs1

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 8d agoAdvisory in the wild

7th September – Threat Intelligence Report

Check Point weekly bulletin: exploited SonicWall SMA 1000 zero-days (CVE-2026-83548/49), JFrog Artifactory auth bypass, and a 2.8M-patient Baylor Genetics breach.

Check Point's weekly bulletin covers breaches including Thomson Reuters' C-Track platform (court records across 11 US states and Canada), Baylor Genetics (2.8M patients and employees, SSNs included), Hit casinos in Slovenia, and Dropbox (~5,000 accounts via abused Lenovo email verification). SonicWall patched two exploited SMA 1000 zero-days, including CVE-2026-83548, a CVSS 10.0 pre-authentication SSRF, while JFrog fixed exploited authentication bypass CVE-2026-82329 (CVSS 9.8). Malware and actor coverage includes Gambling Goblin, JSCeal, Mirage Kitten's NodeRabbit/PollCat campaign, and DPRK Contagious Interview macOS activity, plus a FalconFlank privilege-escalation PoC against CrowdStrike Falcon.

CISA Red Team Compromised Two Critical Infrastructure Orgs, One Detected Nothing

CISA red teams fully compromised two critical infrastructure orgs with similar tradecraft; one detected nothing, the other contained phishing within minutes.

CISA advisory AA26-237A, 'A Tale of Two SOCs,' describes two simultaneous red team assessments of a Government Services organization and a Water and Wastewater Systems organization, both compromised to the domain level. Organization A never detected the intrusion, enabled by default credentials, a misconfigured AD CS template (ESC1), cleartext credentials, non-expiring static AWS keys, and over-permissioned Entra ID applications. Organization B detected and isolated phishing within 2-20 minutes, though the red team still reached krbtgt via DCSync from cleartext SCCM credentials. CISA attributes the outcome gap to people and processes rather than the security tools themselves.

The Hacker News · 22d agoAdvisory