CISA Updates Insider Threat Guide With New Mitigation Advice
CISA updated its Insider Threat Mitigation Guide on September 9 with new case studies and guidance on hybrid work, AI and employee separations.
CISA published a revision of its Insider Threat Mitigation Guide, first issued in 2020, adding case studies, statistics and guidance for security, HR and leadership audiences. New material covers hybrid and remote work changes to physical and digital access, AI used to manipulate or deceive, access control, visitor screening and adverse employee separations. The agency framed the update around growing insider threat impact on critical infrastructure and pointed to preparedness resources for organizations without existing programs.
Microsoft confirms KB5002914 Excel update breaks copy and paste
Microsoft confirms KB5002914 Office security update silently breaks copy-paste, autofill, and formula dragging in Excel 2016 through 2024.
Microsoft confirmed the September 2026 KB5002914 security update breaks copy-and-paste, autofill, and formula dragging in Excel 2024, 2021, 2019, and 2016. Failures occur silently with no beep or error message, leaving the destination unmodified. Uninstalling KB5002914 via OfficeC2RClient or Oarpmany restores functionality while Microsoft investigates.
SolarWinds Database Mapper and Task Factory enable data professionals to accelerate cloud migrations
Schneider Electric SCADAPack x70 Products
CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.
CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.
CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production
CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.
Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.