ZeroHour

Search: “Direct Connect”

63 stories

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 1d agoAdvisoryCVE-2026-81861

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

CISA Shares 17 Techniques Used by Hackers to Compromise Active Directory

CISA and five international agencies publish joint guidance detailing 17 techniques attackers use to compromise Microsoft Active Directory environments.

CISA, NSA, and the Australian Signals Directorate's ACSC, with contributions from Canadian, UK, and New Zealand cyber centers, released technical guidance on 17 Active Directory attack techniques. It covers AD Domain Services, AD Certificate Services, and AD Federation Services, including Kerberoasting, DCSync, Golden Ticket, Golden SAML, Skeleton Key, and Shadow Credentials. The guidance recommends treating domain controllers, CAs, AD FS servers, and Entra Connect systems as Tier 0 assets with phishing-resistant MFA, Kerberos pre-authentication enforcement, and disabling NTLM/SMBv1.

Cyber Security News · 21h agoAdvisory

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

CISA's logging guidance works beyond government

CISA released its Logging Reference Architecture in August 2026 to help federal agencies meet OMB M-26-14 logging requirements, usable as a benchmark by critical infrastructure operators.

CISA's Logging Reference Architecture (LRA), released in August 2026, helps US federal civilian agencies satisfy logging requirements in OMB Memorandum M-26-14 and explicitly encourages critical infrastructure operators to use it as a benchmark. The framework is organized around continuous event monitoring and threat hunting, investigation, response, and forensics, with a federal baseline of six months searchable and one year retrievable logs. Agencies must submit Agency Logging Plans within 90 days and work toward Advanced maturity within 320 days; the guidance also treats AI outputs as derived data requiring human review and preserved metadata.

Help Net Security · 23d agoAdvisory

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 27d agoAdvisory in the wild

Best Practices for Good Endpoint Hardening | Huntress

Huntress outlines endpoint hardening best practices, citing exposed RDP, RMM tool abuse, and ClickFix social engineering as common SMB intrusion paths.

Huntress published defensive guidance on endpoint hardening for small and mid-sized businesses, drawing on observations from its SOC. The post describes common intrusion vectors: internet-exposed RDP brute-forced by automated scanners, phishing emails delivering attacker-controlled remote monitoring and management (RMM) tools, with Huntress reporting a 277% spike in RMM abuse in 2025, and ClickFix attacks using fake CAPTCHA pages that trick users into running malicious commands. Recommended controls include scanning for exposed RDP, SSH, and VPN interfaces, removing unneeded local admin rights, enabling Windows Defender tamper protection, disabling SMBv1, and standardizing on one approved remote access tool, guided by CIS and NIST frameworks.

Huntress · 5d agoAdvisory

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 7d agoAdvisory in the wild

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

CISA Advisories · 1d agoAdvisoryCVE-2026-58113

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465