CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 7d agoAdvisory in the wild

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 27d agoAdvisory in the wild

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

CISA Advisories · 23h agoAdvisoryCVE-2026-81861

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 12d agoAdvisoryCVE-2026-4827