Deep Learning-Based Detection of Electrical Faults and Power Quality Disturbances in Aerospace Power Systems

Compact ResNet detects electrical faults in 400 Hz aircraft power systems with 95.87 percent accuracy after deployment on Xilinx Zynq MPSoC.

The study targets multiclass fault and power quality disturbance detection in 400 Hz aerospace networks using a high-fidelity simulation model inspired by the Boeing 787 electrical architecture, covering 21 normal, disturbance, switching, open-circuit, and short-circuit conditions. Two 73,500-sample datasets are built from 1D waveforms and STFT time-frequency representations, augmented with domain randomization and class-specific GANs, and the time-series dataset is released via IEEE DataPort. A compact ResNet with 175,685 parameters achieved 96.94 percent software test accuracy, and 95.87 percent after 8-bit quantization on a Xilinx Zynq UltraScale Plus ZCU102 with 6.90 ms mean accelerator latency per record.

arXiv cs.AI / cs.LG / cs.CL · 7d agoAI research

Powering AI is an architecture problem

Sponsored analysis argues AI data centers need medium-voltage, inline power architecture after Virginia grid faults knocked over 3GW of load offline.

A sponsored MIT Technology Review piece recounts a July 22, 2026 transmission fault in Ashburn, Virginia that shed more than 3 GW of data center load, and a 2024 incident where one failed surge arrester dropped about 60 facilities and 1,500 MW. It argues legacy UPS-based power stacks fail at AI scale because campuses can swing 70% of load in milliseconds and trip offline during grid disturbances. The proposed fix moves protection to medium voltage (13.8 kV and above) in inline enclosures near substations, improving density, permitting timelines, and backup power economics. A full-scale system tested at the DOE National Laboratory of the Rockies cleared ERCOT large-load ride-through requirements.

MIT Technology Review · AI · 6d agoAI industry1

Wicked Problem, Parsimonious Solution: Securing Electric Vehicle Charging Station Software

Position paper proposes hierarchical software quality assurance to characterize and secure EV charging station software attack surfaces.

The authors argue that charging station supply-equipment software is a largely unprotected and poorly characterized attack surface in EV charging infrastructure. They advocate applying hierarchical software quality assurance (HSQA) to this specialized software, spanning from individual vulnerabilities such as CVEs to high-level characteristics like the CIA Triad. HSQA embeds quality and security considerations across the entire software development lifecycle to assess and improve charging station software security.

arXiv cs.CR · 7d agoResearch

Why Scaling AI Compute Performance Requires a New Power Architecture

NVIDIA argues AI factories need 800 VDC power distribution as dense GPU racks outgrow traditional AC-based delivery.

NVIDIA's blog contends each generation of accelerated computing demands higher rack density and more efficient, scalable power distribution. It frames the bottleneck as how power moves from the grid to the GPU rather than raw wattage, and describes limitations of traditional AC power delivery. NVIDIA advocates a new 800 VDC power architecture for AI factories.

NVIDIA Blog · Aug 11, 2026AI industry

A battery storage cyberattack would look exactly like a badly tuned controller

Risk modeling suggests a few hundred compromised grid-scale batteries dispatched through cloud optimizers could trigger blackouts in Texas or Great Britain.

Centrii analysis estimates 1,500 compromised one-megawatt units (5.4% of ERCOT's ~28 GW fleet) or 400 units (about 29% of Great Britain's ~1,400-unit fleet) could destabilize the grids, with modeled damage of $12-65 billion in Texas and a national blackout costing £2-10 billion in Britain. The study puts the probability of a major attack affecting at least one million people by 2031 at 92.1%, dropping to 61.4% with IEC 62443 certification and quarterly drills, based on 10,000 Monte Carlo runs. Because hostile battery swings are phased like legitimate frequency response, control rooms would see nothing unusual; Centrii proposes hunting for a reverse-governor signature where inverter output feeds oscillations. Spain's April 2025 blackout took an expert panel until March 2026 to rule out cyberattack, partly because key plants had no recordings.

Help Net Security · 15d agoResearch

From Megawatts to Tokens: How NVIDIA Maximizes AI Factory Production

NVIDIA detailed DSX power-management results: Lambda gained 24% token throughput at fixed power, and an AI factory auto-shed 1MW via Emerald AI's grid program.

NVIDIA says Lambda's first validation of DSX MaxLPS on HGX B200 servers ran 19 nodes within a 16-node power budget, lifting cluster token throughput 24% (roughly 4M to 5M tokens/second) and improving performance per watt by 23%. NVIDIA projects DSX MaxLPS can enable up to 40% more GPU capacity for Vera Rubin NVL72 factories within the same megawatt budget. Emerald AI's Conductor platform, running at NVIDIA's Eos factory with Silicon Valley Power, responded to over 200 utility demand signals, automatically dropping power from 4MW to 3MW without interrupting priority workloads. The first dedicated DSX Flex commercial deployment is planned at a 96-megawatt Manassas, Virginia facility.

NVIDIA Blog · 1d agoAI industry

Massachusetts hits data centers with new clean power rules

Massachusetts executive order requires data centers over 25 MW to supply 100% clean power, fund nearby generation, or pay a ratepayer protection fund.

Governor Maura Healey's executive order requires developers building data centers larger than 25 megawatts of peak demand to bring their own power that meets 100% of the state's clean energy standard, fund new generation nearby, or pay into a ratepayer protection fund. Massachusetts is the third state in three months to restrict data center development, following Texas utility audits (ERCOT) and New York's pause on 50 MW-plus projects. The state is also pausing applications for a data center sales tax exemption and directing communities to avoid non-disclosure agreements. Pro-AI super PAC Leading the Future, funded by Marc Andreessen, Ben Horowitz, and Greg Brockman, is running ads ahead of midterms as industry pushes back.

TechCrunch · AI · 7d agoAI policy

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

What Breaks Under Pruning in Smart Homes, and When? Evaluating LLM Degradation Across Architectures and Task Complexity

Pruning study across four LLM architectures finds dense models degrade sharply on smart-home tool calling while MoE models tolerate far more.

Researchers systematically study pruning-induced degradation in smart-home tool calling across four LLMs spanning dense Transformer, dense hybrid, and mixture-of-experts architectures, combining depth, width, hybrid, and expert pruning methods, and evaluate over 19,500 instances from three datasets after post-pruning supervised fine-tuning. Dense models show narrow safe pruning regions followed by sharp degradation, while MoE models tolerate substantially more pruning. Pruning degrades grounded specificity (operation, device, argument, value) before schema-level intent, and aggressive dense pruning can induce systematic over-refusal.

arXiv cs.AI / cs.LG / cs.CL · 1d agoAI research

Cybersecurity in Power Grids: Standards and Research Challenges

Survey contrasts IT and OT security in smart grids, reviewing IEC 62351, IEC 62443, ISO 27001 standards and AI-driven detection trends.

The paper examines Smart Grid cybersecurity, emphasizing critical distinctions between IT and OT environments. It analyzes grid architecture, substation threats, and key international standards including IEC 62351, IEC 62443, and ISO 27001. It concludes with an overview of recent research trends such as AI-driven threat detection.

arXiv cs.CR · 1d agoResearch

TPMSpy: Validation of Measured Boot Systems by Low-Level Tracing of TPM Usage

Researchers present TPMSpy, a platform-agnostic method validating TPM Measured Boot via low-level tracing, finding inconsistent Linux systemd measurements that break remote attestation and LUKS decryption.

An arXiv paper (2609.05011) introduces TPMSpy, a method that analyzes virtualized system–TPM interactions to independently reconstruct and validate TPM Event Logs without relying on the quoting mechanism, applicable to open and closed systems and demonstrated on Linux and Windows. A longitudinal analysis of Linux systems running systemd versions 245–258 (2020–2025) found wide divergence in Measured Boot usage, undocumented behavioral changes, and no common usage pattern. The authors report inconsistent measurement of user-space systemd services, which prevents reliable remote attestation and LUKS disk decryption on affected systems.

arXiv cs.CR · 12d agoResearch

[Control systems] Schneider Electric security advisory (AV26-871)

Canada's Cyber Centre relayed Schneider Electric advisories for vulnerabilities in NetBotz 5-750/755 (5.5.2 and prior) and PowerChute Serial Shutdown (1.5 and prior).

The Canadian Centre for Cyber Security issued control-systems advisory AV26-871 noting Schneider Electric products affected by vulnerabilities as of September 1, 2026. Affected products include NetBotz 5-750/755 versions 5.5.2 and prior, and PowerChute Serial Shutdown versions 1.5 and prior, the latter with an improper restriction of excessive authentication attempts flaw. Administrators are urged to review Schneider Electric's security notifications and apply the suggested mitigations and updates.

Canadian Centre for Cyber Security · 14d agoAdvisory

Injected and Leaked: Actively Inducing Side-Channel Leakage Using Electromagnetic Injection and Hardware Nonlinearity

Researchers introduce InjectEave, using electromagnetic injection and hardware nonlinearity to induce side-channel leakage and eavesdrop on headphone audio from 30 meters.

An arXiv paper shows electromagnetic injection can actively amplify side-channel leakage: nonlinear hardware such as amplifiers, ADCs, and power converters modulates secret electrical signals onto an injected EM carrier, upconverting low-frequency secrets into measurable EM emissions. By tuning injection frequency and amplitude, an adversary can shape the effective spectrum and entropy of the resulting leakage. The InjectEave attack demonstrated eavesdropping on wired and wireless headphone audio from up to 30 meters and in through-wall scenarios using accessible RF equipment, plus leakage of smart home device power consumption and analog sensor inputs. Case studies show closed-loop eavesdropping and manipulation of landline phone conversations, and the paper discusses mitigations.

arXiv cs.CR · 12d agoResearch

[Control systems] Schneider Electric security advisory (AV26-912)

Canada's Cyber Centre relays a Schneider Electric advisory covering multiple vulnerabilities in EcoStruxure IT Data Center Expert and PowerLogic T300, urging users to apply updates.

The Canadian Centre for Cyber Security issued advisory AV26-912 noting that as of September 9, 2026 Schneider Electric is affected by vulnerabilities in EcoStruxure IT Data Center Expert versions 9.1.2 and prior, and PowerLogic T300 versions 2.9.8-5620 and prior. The issues include an improper neutralization of special elements used in an OS command on the PowerLogic T300. The advisory recommends reviewing vendor notifications, performing suggested mitigations, and applying necessary updates.

Canadian Centre for Cyber Security · 5d agoAdvisory

Emergency Department Revisit Quality Review Screening: Exploring Human Decision-Making and Artificial Intelligence Support

A retrospective study found GPT-4 over-flagged emergency department revisit cases while an LLM knowledge-graph screener achieved 83-100% positive predictive value.

In an exploratory retrospective study of 99 emergency department diagnosis pairs from a multihospital health system, clinicians and GPT-4 independently judged whether revisit pairs warranted further assessment. GPT-4 responses correlated poorly with clinicians, flagging 94% of pairs for follow-up, 4.4-13.3 times more than clinicians, though prompt engineering was minimal. An algorithm leveraging an LLM-populated knowledge graph (KGA) achieved 83-100% positive predictive value against at least one clinician rater, suggesting LLM-based screening could broaden revisit quality review without substantially increasing reviewer workload.

arXiv cs.AI / cs.LG / cs.CL · 7d agoAI research1

Your Critical Vulnerabilities Might Not Be Your Biggest Risk

Autonomous penetration testing advocates prioritize exploitable attack paths over raw vulnerability severity for continuous security validation.

The article argues that scanner severity scores lack context: a critical flaw behind strong segmentation may be low priority, while a medium flaw on internet-facing systems can provide a foothold chained toward sensitive data. It positions autonomous penetration testing and attack path validation as the execution layer for continuous security validation, replacing point-in-time assessments. The piece is vendor-authored thought leadership rather than incident or vulnerability news.

The Hacker News · 5d agoIndustry1

How CHERIoT Provides Strong and Usable Isolation Without an MMU

ACM Queue paper explains how CHERIoT uses CHERI hardware capabilities to give microcontroller-class IoT devices memory and privilege isolation without an MMU.

The ACM Queue article (DOI 10.1145/3831361) describes CHERIoT, a RISC-V-derived platform that scales CHERI capability-based hardware down to small embedded and IoT microcontrollers. It provides strong, fine-grained isolation and memory safety without a memory management unit, aiming to make compartmentalization practical for low-cost devices. The piece emphasizes usability of the isolation model alongside its security guarantees.

Lobsters · security · 6d agoResearch

Verify Before You Distill: Prompt-Level Teacher Gating for On-Policy Distillation

TGOPD verifies teacher reliability per prompt before on-policy distillation, outperforming vanilla OPD across math, code, and instruction benchmarks.

Teacher-Gated On-Policy Distillation (TGOPD) estimates teacher reliability from verifier-scored teacher probes and routes each prompt either to dense on-policy distillation or to verifier-grounded GRPO, avoiding misleading updates from confidently wrong teachers under mode-seeking reverse KL. Across 4B and 35B students in mathematics, code, and instruction following, TGOPD outperforms vanilla OPD in all six single-domain settings and achieves higher seven-benchmark averages under multi-domain training. It also raises teacher-node GPU utilization from 9.8% to 78.9% in the measured 4B single-domain run by reusing idle teacher capacity.

Hugging Face daily papers · 15d agoAI research

CertiFlash: A Formal Verification Framework for Flash Translation Layers in Computational Solid State Drives

CertiFlash provides machine-checked formal verification of SSD flash translation layers, proving isolation, integrity, and ownership invariants to prevent tenant data leaks.

CertiFlash is an open-source formal verification framework for Flash Translation Layers (FTL) in computational SSDs, mechanized in the Rocq proof assistant. It shows that a faulty FTL can corrupt device state at five surfaces (e.g., leaking data between tenants or dropping integrity tags), demonstrated on a DaisyPlus OpenSSD. Designers prove once that every operation of a general FTL model preserves a global invariant covering mapping, isolation, integrity, ownership, and allocation; new designs need only discharge five hypotheses. Across four case studies, added effort was 27-3,231 lines against a 16,489-line framework.

arXiv cs.CR · 7d agoResearch1

Evaluating Time-Series Foundation Models and Multimodal Dietary Context for CGM Forecasting

Study finds zero-shot time-series foundation models underperform on CGM forecasting; fine-tuned Chronos-Bolt cuts RMSE up to 18.4% and dietary context adds signal.

The paper evaluates time-series foundation models for continuous glucose monitoring forecasting across eight public datasets covering Type 1 diabetes, Type 2 diabetes, and non-diabetes populations. Under a unified protocol, zero-shot foundation models did not consistently outperform baselines like Elastic Net and PatchTST, but lightweight fine-tuning did, with fine-tuned Chronos-Bolt reducing RMSE by 6.5%-18.4% in the T1D cohort and 8.6%-18.2% in the non-diabetes/T2D cohort. A residual-based fusion framework adding dietary context from CGMacros reduced overall RMSE by about 3% and postprandial RMSE by about 15% versus CGM-only baselines.

arXiv cs.AI / cs.LG / cs.CL · 6d agoAI research

Quantifying IIoT Sensor Node Criticality by Fusing its Data Criticality and Security Vulnerability

Researchers propose a Dempster–Shafer framework fusing IIoT sensor data criticality with CVSS 4.0/3.1 vulnerability scores to rank node criticality.

The paper introduces a framework that evaluates Industrial IoT sensor node criticality by fusing data criticality and cybersecurity vulnerability scores using Dempster–Shafer (D-S) theory. It was validated on a dataset from red wine production and is claimed to generalize to other industrial settings with minimal modification. Results show criticality rankings derived from CVSS 4.0 scores differ significantly from those derived from CVSS 3.1, underscoring how vulnerability scoring methodology affects security prioritization.

arXiv cs.CR · 7d agoResearch

Bipartisan Senate bill aims to prepare energy sector for Q

Bipartisan Senate bill would direct FERC to factor quantum computing threats and post-quantum cryptography into US electric grid cybersecurity reliability standards.

The Quantum Grid Utility Assurance and Resilient Defense (Quantum-GUARD) Act, introduced by Senators Mike Rounds and Chris Coons, would require FERC to consider quantum computing threats when reviewing electric reliability standards and to explore post-quantum cryptography use in both IT and OT systems, plus a technical sandbox to study quantum impacts. It aligns with NIST's post-quantum algorithm work, and a June executive order moved the federal PQC migration deadline from 2035 to 2030. Industry experts noted the hard part is upgrading infrastructure such as SCADA communications and software update integrity ahead of those deadlines.

CyberScoop · 23d agoPolicy & legal

Adversarial Testing of Automated Program Repair Agents for Security Vulnerabilities

SWEADV benchmark shows adversarial issue descriptions make LLM program-repair agents write insecure fixes in 51.7% of cases, evading most detection tools.

Researchers built SWEADV, a benchmark of 750 adversarial issue descriptions derived from 150 SWE-bench Verified repair tasks, covering command execution, deserialization, path traversal, denial of service, and weak hashing attack types. Tested on mini_swe agents backed by GPT-5-Mini, MiniMax-M2.5, and DeepSeek-R, adversarial descriptions induced malicious behavior with successful repair in 51.7% of cases. Detection was weak: LLM-as-judge pre-repair screening reached only 62.3% accuracy, and post-repair detection via static analysis and LLM-as-judge achieved just 39.4% and 55.4%.

arXiv cs.CR · 2d agoAI safety & security2

White House bans foreign-made equipment for power generation over cyber backdoor concerns

Trump executive order bans acquisition of foreign-made bulk-power system equipment over cyber backdoor and supply-chain concerns for US electricity infrastructure.

The White House issued an executive order declaring foreign-made bulk-power system electric equipment an "unusual and extraordinary threat," banning its acquisition or installation in the US. The order covers technology managing transmission lines rated at 69,000 volts or higher, substations, control rooms, power generating stations, reactors, and associated remotely accessible software and firmware. It follows recent cyberattacks on water utilities in at least 12 states, malicious activity targeting over 100 internet-exposed water and wastewater systems, and an NSA/FBI advisory on an AI-powered threat to operational technology. The Defense, Commerce, and Energy Departments have 120 days to create rules, identify countries warranting scrutiny, and inventory at-risk equipment.

The Record · 20d agoPolicy & legal

ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws

September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.

Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.

Perturbation Probing: A New Diagnostic for the Fragility of LLM Safety

Unit 42 research shows LLM safety refusals concentrate in a thin neural layer, motivating external, multi-layered AI security controls.

Palo Alto Networks Unit 42 introduces Perturbation Probing, a diagnostic technique for measuring the fragility of LLM safety mechanisms. The research finds that safety refusal behavior is localized within a thin neural layer, implying small perturbations can undermine built-in refusals. The authors argue this motivates external, multi-layered security defenses on top of model-internal safety training.

Palo Alto Unit 42 · 19d agoAI safety & security

A Ranking Approach for Measuring Calibration

Researchers propose rankECE, a ranking-based calibration error measure with theoretical guarantees that outperforms binned ECE approximations.

The paper introduces rankECE, an alternative to Expected Calibration Error (ECE) that measures miscalibration by comparing points with neighboring predicted-probability values. It addresses the impossibility of estimating ECE with guaranteed accuracy in assumption-free settings. Theoretical guarantees and empirical results establish rankECE as a better proxy for ECE than the binned approximations most commonly used in practice.

arXiv cs.AI / cs.LG / cs.CL · 5d agoAI research1

Bridging the Confidence Gap: Temperature Scaling for Calibrating Test-Time Prompt Tuning

CoTS temperature scaling cuts test-time prompt tuning's expected calibration error from 11.90% to 5.38% on ImageNet variants while raising accuracy.

The paper proposes CoTS, a post-hoc calibration method that applies temperature scaling to minimize the confidence gap between test-time-adapted and zero-shot predictions. A weak-strong ensemble variant, E-CoTS, further exploits multiple test-time augmentations to boost accuracy while maintaining calibration. E-CoTS reduces average expected calibration error from 11.90% to 5.38% on ImageNet variants while increasing accuracy from 60.74% to 62.95%.

arXiv cs.AI / cs.LG / cs.CL · 1d agoAI research

FreqSpaNet: Frequency and Spatial Learning of SFPF for Physical Layer Hardware Integrity Detection

FreqSpaNet learns spatio-frequency polarization fingerprints to detect unauthorized wireless hardware replacement, reaching 96.31% mean AUROC across seven replacement scenarios.

FreqSpaNet is a representation learning network for open-set hardware anomaly detection using spatio-frequency polarization fingerprints (SFPFs), which capture device-dependent responses across frequencies and directions. A frequency branch models local variations among neighboring frequencies while a geometry-aware spatial branch models directional relationships via angular information, combined through adaptive fusion and complementary pretraining. It achieves a mean AUROC of 96.31%, 9.05 points above the baseline, and is verified under seven hardware replacement scenarios.

arXiv cs.AI / cs.LG / cs.CL · 1d agoAI research1

[Control Systems] National Instruments security advisory (AV26-856)

Canada's Cyber Centre relayed National Instruments advisories for memory corruption, out-of-bounds read, and out-of-bounds write flaws in LabVIEW versions.

The Canadian Centre for Cyber Security published control systems advisory AV26-856 covering National Instruments LabVIEW. Affected versions include releases before 23.0.0, 23.3.10, 24.3.7, 25.3.5, and 26.3.1. The flaws include memory corruption, an integer conversion out-of-bounds read, and an integer overflow out-of-bounds write. Users and administrators are urged to review the links and apply NI security updates.

Canadian Centre for Cyber Security · 19d agoAdvisory