Hackers Actively Exploit Critical WooCommerce Plugin Vulnerability to Upload PHP Backdoors
Attackers actively exploit CVE-2026-27540 (CVSS 9.8) in WooCommerce Wholesale Lead Capture plugin to upload PHP webshells; patch shipped in version 2.0.3.2.
CVE-2026-27540 (CVSS 9.8) in the WooCommerce Wholesale Lead Capture plugin affects versions 2.0.3.1 and earlier across roughly 6,000 active installations. The unauthenticated AJAX handler wwlc_file_upload_handler trusts a client-supplied file_settings allowlist, letting attackers upload shell.php for remote code execution. Wordfence has blocked more than 100,000 exploit attempts since disclosure, with spikes in June, July, and August 2026. The vendor fixed the flaw in version 2.0.3.2.
ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws
September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.
Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.
Hackers Exploit Critical FortiGate Flaw to Deploy AI-Assisted PivotC2 RAT
SOCRadar says attackers exploit FortiGate CVE-2025-25249 to deploy the PivotC2 Node.js RAT, compromising 178 of 30,000 targeted devices and stealing credentials.
SOCRadar's Threat Research Unit reports active exploitation of CVE-2025-25249, a CVSS 9.8 heap-based buffer overflow in the cw_acd daemon of FortiOS and FortiSwitchManager, via crafted CAPWAP requests to UDP port 5246, compromising at least 178 of 30,000 targeted internet-exposed FortiGate devices since July 2026. The campaign deploys PivotC2, a Node.js RAT that provides interactive shells, SOCKS5/HTTP proxying, port forwarding, network scanning, and automated configuration harvesting that decrypts stored FortiGate credentials, including VPN pre-shared keys, SSL-VPN credentials, and LDAP secrets. Russian-language artifacts, AD enumeration, browser credential theft, RDP enablement, and exfiltration of Exchange .pst files to Wasabi S3 point to a Russian-speaking, financially motivated group; two US organizations confirmed full-network intrusions. Fixes include FortiOS 7.6.4/7.4.9/7.2.12/7.0.18+ and FortiSwitchManager 7.2.7/7.0.6+, plus blocking CAPWAP on internet-facing interfaces.
CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production
CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.
Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.
Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)
CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.
CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.