Schneider Electric SCADAPack x70 Products
CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.
CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.
Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)
CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.
CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.
New Mirai-Based Evooo1Bot Botnet Targets Linux Devices
FortiGuard Labs disclosed Evooo1Bot, a Mirai-based Linux botnet active since July 2026 that hijacks routers and IoT devices for DDoS, credential theft, and SOCKS5 proxying.
Fortinet's FortiGuard Labs disclosed Evooo1Bot, a previously undocumented Linux botnet active since July 2026 that reuses Mirai's DDoS engine while adding encrypted C2, SSH brute-force scanning, credential sniffing, and SOCKS5 proxy modules. The bot exploits 18 known CVEs across Alcatel, NETGEAR, Tenda, D-Link, Telesquare, and Mitsubishi devices, some dating back to 2007, and communicates exclusively over port 443 to blend with HTTPS traffic. Compromised hosts can be turned into SOCKS5 relays for anonymous traffic forwarding or monetization via proxy services. The malware uses AES-256-CTR, ChaCha20, and XOR obfuscation with a 28-command administration interface.
Evooo1Bot Linux Botnet Exploits Known Flaws to Turn Edge Devices Into SOCKS5 Proxies
Fortinet researchers documented Evooo1Bot, a new Mirai-derived Linux botnet active since July 2026 that exploits known edge-device flaws to build SOCKS5 proxy networks.
Fortinet FortiGuard Labs identified Evooo1Bot, a previously undocumented Linux botnet built on the leaked Mirai source code, active in the wild since July 2026 and targeting internet-facing edge devices. It exploits numerous known CVEs in routers and devices from D-Link, Tenda, Telesquare, Zyxel, Hikvision, Atlassian Confluence, WSO2, TP-Link, NETGEAR, and others, delivering a bot binary via a wget.sh loader from 91.92.40.118 that clears bash history. The bot offers encrypted C2 on port 443, SSH brute-force scanning, credential sniffing, DDoS over DNS/TCP/UDP, an HTTP exploit dispatcher, and converts infected hosts into SOCKS5 proxies for anonymizing follow-on operations.
ICS Patch Tuesday: Schneider Electric, Siemens Fix Critical Flaws
September ICS Patch Tuesday brings critical fixes from Schneider Electric, Siemens, and Aveva, including CVSS 9.2 authentication flaw CVE-2026-3869 in Modicon M580 controllers.
Schneider Electric's September advisories include a critical authentication vulnerability, CVE-2026-3869 with a CVSS score of 9.2, in Modicon M580 and Modicon M580 Safety controllers, plus high-severity bugs in PowerLogic T300 and EcoStruxure IT Data Center Expert. Siemens published nine new advisories, four rated critical across Reyrolle 7SR5, Open Interface Services, Industrial Edge Management, and SIMOVE Fleetmanager and SIPLANT, and began rolling out fixes for CVE-2026-31431, a 7.8-rated Linux kernel flaw enabling root shell access. Aveva disclosed four flaws in Pipeline Integrity Monitor's PIMBoards, including a hardcoded encryption key and MD5-hashed passwords, plus an unsafe deserialization issue in Enterprise SCADA. Rockwell Automation separately issued nine advisories covering RSLinx Classic and multiple controller products.
CISA Warns Water Utilities: Find Your Exposed PLCs Before Attackers Do
CISA urged water utilities to secure internet-exposed PLCs after July 2026 attacks compromised over 100 US water and wastewater systems, suspected Iran-linked.
CISA's exposure-reduction guidance, published August 21, follows July 2026 attacks in which threat actors remotely accessed PLCs connected directly through cellular modems, changed device IP addresses and passwords, and in some cases disabled alarms and shutdown processes without notifying operators. Iran is the suspected actor, though officials stopped short of formal attribution. CISA recommends routing remote access through centrally managed secure gateways, phishing-resistant MFA, unique credentials, and external scanning of industrial protocols such as Modbus, EtherNet/IP, DNP3, BACnet and OPC UA.