CISA and Schneider Electric Issue Advisories for Modicon M340, NetBotz 5 750/755, and PowerChute Serial Shutdown
CISA and Schneider Electric published advisories covering four vulnerabilities — CVE-2025-6625, CVE-2026-13336, CVE-2026-13337, and CVE-2026-13348 — across Modicon M340 controllers/communication modules, NetBotz 5 750/755 environmental monitors, and…
Per CISA advisory reports dated 2026-09-17, CISA and Schneider Electric released advisories for four flaws across three Schneider Electric product lines. Advisory SEVD-2025-224-05 (republished by CISA) describes CVE-2025-6625 (CWE-20 improper input validation, CVSS v3.1 base score 7.5) in Modicon M340 controllers and X80 Ethernet, M580 Global Data, and Modbus/TCP communication modules: a crafted FTP command sent to an affected device causes denial of service. Affected M340 firmware is prior to SV3.70, and fixes are available including M340 firmware SV3.70. Advisory ICSA-26-260-05 covers NetBotz 5 750/755 environmental monitors running versions 5.5.2 and prior: CVE-2026-13336 (CWE-78 OS command injection, CVSS 6.4) allows Linux command execution when a maliciously modified system backup is restored, and CVE-2026-13337 (CWE-564 Hibernate SQL injection, CVSS 4.6) allows HQL injection into the NetBotz database via the web service or web UI; successful exploitation could enable code execution, device manipulation, and unauthorized data access on the local network. Advisory ICSA-26-260-07 covers CVE-2026-13348 (CWE-307 improper restriction of excessive authentication attempts, CVSS 3.1 score 5.3) in PowerChute Serial Shutdown versions 1.5 and prior, which lets attackers perform an arbitrary number of authentication attempts when redirect handling is disabled, gaining unauthorized access to user accounts; the UPS management software is deployed across commercial facilities, critical manufacturing, energy, and IT sectors worldwide, and CISA recommends network isolation, VPN-protected remote access, and applying the vendor fix. Fixes are available for all four flaws. The NetBotz and PowerChute advisories report no indication of exploitation in the wild; the Modicon M340 advisory does not state an exploitation status.
- CVE-2025-6625 (CWE-20 improper input validation, CVSS v3.1 7.5): crafted FTP command causes denial of service on Modicon M340 controllers and X80 Ethernet, M580 Global Data, and Modbus/TCP modules; affects M340 firmware before SV3.70;…
- CVE-2026-13336 (CWE-78 OS command injection, CVSS 6.4): Linux command execution possible when a maliciously modified system backup is restored on NetBotz 5 750/755 versions 5.5.2 and prior
- CVE-2026-13337 (CWE-564 Hibernate SQL injection, CVSS 4.6): HQL injection into the NetBotz database via the web service or web UI on NetBotz 5 750/755 versions 5.5.2 and prior; both NetBotz flaws tracked in advisory ICSA-26-260-05 with…
- CVE-2026-13348 (CWE-307, CVSS 3.1 5.3): PowerChute Serial Shutdown versions 1.5 and prior lack brute-force protection when redirect handling is disabled, allowing unauthorized account access via unlimited authentication attempts; tracked…
- CISA mitigation guidance for PowerChute Serial Shutdown: network isolation, VPN-protected remote access, and applying the vendor fix; the software is deployed in commercial facilities, critical manufacturing, energy, and IT sectors…
- No indication of exploitation in the wild reported for the NetBotz (CVE-2026-13336, CVE-2026-13337) or PowerChute (CVE-2026-13348) flaws; the Modicon M340 advisory does not state exploitation status
Coverage timelineoldest first · each row is one article
- · 1d agoSchneider Electric NetBotz 5 750/755
CISA Advisories· 25
CISA and Schneider Electric issued an advisory for NetBotz 5 750/755 covering OS command injection and Hibernate SQL injection flaws in versions 5.5.2 and prior.
- · 1d agoSchneider Electric PowerChute Serial Shutdown
CISA Advisories· 20
CISA and Schneider Electric warn that PowerChute Serial Shutdown 1.5 and prior lack brute-force protection, allowing unauthorized account access via unlimited authentication attempts.
- · 1d agoSchneider Electric Modicon M340 Controller and Communication Modules
CISA Advisories· 32
CISA warns CVE-2025-6625 lets unauthenticated attackers crash Schneider Electric Modicon M340 controllers and communication modules via a crafted FTP command.
Vulnerabilities in this storyAll →
| CVE | Vulnerability | CVSS | EPSS | Flags | Affected | Exposure | Published |
|---|---|---|---|---|---|---|---|
| CVE-2025-6625 | CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. NVD description · AI analysis pending | 8.7 | <1% | — | — | ||
| CVE-2026-13336 | OS Command Injection via Malicious Backup Restore in Schneider Electric Product CVE-2026-13336 is an OS command injection flaw (CWE-78) in the backup/restore functionality of an affected Schneider Electric product, assigned by Schneider Electric's CNA. It is triggered when an administrator restores a system backup file that has been maliciously modified, causing arbitrary Linux operating system commands to be executed on the device during the restore. Because the CVSS 4.0 vector requires high privileges (PR:H), an adjacent network position (AV:A), and specialized attack conditions (AT:P), exploitation most plausibly requires an attacker who can tamper with a backup file or its storage location, such as an insider or an attacker with access to the network path or backup repository. Successful exploitation yields high impact to confidentiality, integrity, and availability on the vulnerable system (VC:H/VI:H/VA:H), effectively full command execution on the underlying Linux OS. As of this analysis there is no known exploitation, no public proof-of-concept, it is not in the CISA KEV catalog, and EPSS estimates only a 0.6% chance of exploitation in the next 30 days. Do: Monitor Schneider Electric's security notifications (SEVD) referenced by this CVE and apply the patched firmware or software version once identified in the vendor advisory. Until patched, only restore backups from trusted sources, verify the integrity of backup files (e.g., checksums) before restoring, and restrict access to backup storage and administrative/restore interfaces on the affected device. Given the AV:A attack vector, segment administrative access to the device from untrusted adjacent networks. | 7.3 | <1% |
| — | ||
| CVE-2026-13337 | Authenticated HQL Injection in Schneider Electric NetBotz 5 750/755 CVE-2026-13337 is an SQL injection flaw (CWE-564) in the Hibernate layer of Schneider Electric NetBotz appliances, allowing a malicious HQL query to be injected into the NetBotz database. Triggering it requires an attacker to already hold valid login credentials and reach the appliance over the network (adjacent network vector, low privileges, no user interaction), submitting the crafted query via the web-service interface or the web UI. A successful injection yields low-level confidentiality and integrity impact — reading or altering data in the NetBotz monitoring database — rather than full system compromise. Only users of the Schneider Electric NetBotz 5 750 and 755 monitoring appliances are affected. There is no evidence of exploitation: no public proof-of-concept, not listed in CISA KEV, and EPSS puts 30-day exploitation probability at just 0.2%. Do: Upgrade NetBotz 5 750/755 appliances to the fixed firmware identified in Schneider Electric's security advisory (SEVD) for CVE-2026-13337. Until patched, restrict access to the web UI and web-service interface to trusted management networks only, since exploitation requires authenticated access. Review and rotate appliance user accounts and monitor NetBotz database activity for unexpected HQL queries or data changes. | 5.1 | <1% |
| nichelikely thousands to low tens of thousands of appliances deployed globally; no public scan or install data for this specific model pair | ||
| CVE-2026-13348 | Password brute-force flaw in Schneider Electric PowerChute Serial Shutdown Schneider Electric PowerChute Serial Shutdown, the management agent used with APC UPS devices, contains an improper restriction of excessive authentication attempts (CWE-307) that allows an unauthenticated attacker to make an arbitrary number of login attempts against a user account. The weakness manifests when redirect handling is disabled, in which case the software fails to enforce account lockout or rate limiting, enabling an online password brute-force attack. An attacker who succeeds gains unauthorized access to a PowerChute account; the CVSS 4.0 vector indicates low confidentiality impact with no direct integrity or availability impact, so the primary risk is unauthorized visibility into and use of a valid account. Any organization running the affected software is potentially affected, though installations whose web interface is reachable only from trusted internal networks face materially lower risk. No public proof-of-concept, CISA KEV listing, or confirmed in-the-wild exploitation is known; EPSS currently estimates a 0.3% probability of exploitation within 30 days. Do: Update PowerChute Serial Shutdown to the fixed release identified in Schneider Electric's security notification as soon as it is available. Until then, restrict access to the PowerChute web interface to trusted management networks using firewall rules, verify whether redirect handling has been disabled in your configuration (the condition under which the lockout bypass occurs), use strong unique credentials for PowerChute accounts, and monitor authentication logs for repeated failed login attempts. | 6.9 | <1% |
| largeon the order of 100,000+ installations worldwide (internet-exposed subset unknown and likely far smaller) |