CVE-2026-13348

Password brute-force flaw in Schneider Electric PowerChute Serial Shutdown

CVSS 4.0
6.9 medium
EPSS
<1%p24
Published
·
Modified
Analyze CVE-2026-13348 with Vani AIImpact, affected versions, exploitation status, mitigations and detection

Schneider Electric PowerChute Serial Shutdown, the management agent used with APC UPS devices, contains an improper restriction of excessive authentication attempts (CWE-307) that allows an unauthenticated attacker to make an arbitrary number of login attempts against a user account. The weakness manifests when redirect handling is disabled, in which case the software fails to enforce account lockout or rate limiting, enabling an online password brute-force attack. An attacker who succeeds gains unauthorized access to a PowerChute account; the CVSS 4.0 vector indicates low confidentiality impact with no direct integrity or availability impact, so the primary risk is unauthorized visibility into and use of a valid account. Any organization running the affected software is potentially affected, though installations whose web interface is reachable only from trusted internal networks face materially lower risk. No public proof-of-concept, CISA KEV listing, or confirmed in-the-wild exploitation is known; EPSS currently estimates a 0.3% probability of exploitation within 30 days.

What to do: Update PowerChute Serial Shutdown to the fixed release identified in Schneider Electric's security notification as soon as it is available. Until then, restrict access to the PowerChute web interface to trusted management networks using firewall rules, verify whether redirect handling has been disabled in your configuration (the condition under which the lockout bypass occurs), use strong unique credentials for PowerChute accounts, and monitor authentication logs for repeated failed login attempts.

ProductAffected
Schneider Electric PowerChute Serial Shutdown—
Estimated exposure
largeon the order of 100,000+ installations worldwide (internet-exposed subset unknown and likely far smaller) — APC/Schneider Electric is the dominant UPS vendor and PowerChute Serial Shutdown ships as the management agent for serial-connected APC UPS models in server rooms and edge sites, implying a very broad installed base, though the web…

Order-of-magnitude estimate by the model from install counts, market share and public scan data it knows; verify before quoting.

Description · NVD

CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled.

Weakness
CWE-307
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X