Skip to content
NewA calmer, faster ZeroHour

Siemens SIMATIC NTLM flaw lets on-path attackers hijack sessions

Original title: Siemens SIMATIC

CISA Advisoriesby CISA ()5 min read2
Part of a story covered by 8 sourcesCISA republishes eight Siemens advisories; three still lack fixesMerged summary & timeline
AI summary · x-ai/grok-4.7Summaries by Vani AI

CVE-2026-58114, CVSS 7.5, affects 14 SIMATIC products with no fix available or planned.

CISA republished a Siemens advisory on CVE-2026-58114 in multiple SIMATIC products used in critical manufacturing. Affected systems do not properly secure remote user authentication with deprecated NTLM, so an unauthenticated attacker in a machine-in-the-middle position can relay authentication, impersonate a user, and run code with that user's privileges. Siemens lists no fix for the affected releases and points customers to encrypting SQL Server communication.

Unconfirmed: The advisory does not say whether the flaw is being exploited.

Key facts
  • CVSS v3 base score is 7.5.
  • Impact depends on reachable services, such as a WinCC SQL server.
  • BATCH, PCS 7, Information Server, and Process Historian have no fix planned.
  • WinCC and WinCC Runtime Professional releases have no fix available.
  • Products are deployed worldwide; Siemens is headquartered in Germany.
Security assessment · AI, from the article

Impact: Impersonate a user and run code as that user

ProductAffected
Siemens SIMATIC BATCH V9.1all/*
Siemens SIMATIC Information Server 2020all/*
Siemens SIMATIC Information Server 2022all/*
Siemens SIMATIC PCS 7 V9.1all/*
Siemens SIMATIC Process Historian 2020all/*
Siemens SIMATIC Process Historian 2022all/*
Siemens SIMATIC WinCC Runtime ProfessionalV17, V18, V19, V20, V21 (all/*)
Siemens SIMATIC WinCCV7.5, V8.0, V8.1 (all/*)
What to do
  1. 1.Manually configure the SQL Server database to encrypt communication using Siemens guidance.
Analyze CVE-2026-58114 with Vani AIImpact, affected versions, exploitation, mitigations and detection

Vulnerabilities mentioned

All
CVEVulnerabilityCVSSEPSSSignalsPublished
CVE-2026-58114
NTLM authentication relay in Siemens SIMATIC products
7.7—

From the original article

5 min read at cisa.gov

View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.

CISA Advisories

By CISA · cisa.gov

Read the full article at CISA Advisories

A short excerpt; the article and its images belong to the publisher. Summary, key facts and assessment above are AI-written from the article and can be wrong.