CISA republishes eight Siemens advisories; three still lack fixes
November 17 republication also covers RUGGEDCOM APE1808: every listed build is affected by Fortinet CVE-2026-106175, and Siemens tells customers to update Fortigate NGFW to V7.6.9.
CISA on November 17 republished eight Siemens advisories; five have fixes, three do not, and exploitation is not reported.
On November 17, 2026, CISA republished eight Siemens ProductCERT advisories covering industrial and engineering software used in critical manufacturing and, in some cases, energy. Fixes are available for Mendix Studio Pro (V11.16.0 and V11.12.7), the SIMATIC S7 .NET client library (V3.3.62), Simcenter Femap (V2606.0002), ROS# (V2.3.1), and RUGGEDCOM APE1808 via Fortigate NGFW V7.6.9. SIMATIC products affected by NTLM relay flaw CVE-2026-58114 have no fix available or planned; Siemens points customers to encrypting SQL Server communication. All SIMATIC WinCC V7.5, V8.0, and V8.1 releases, and meta-iot2050 from V01.03.01, also lack fixes that Siemens says it is preparing. None of the advisories report exploitation.
- CVE-2026-58114, CVSS 7.5, has no fix planned for 14 SIMATIC products.
- Mendix Studio Pro fixes are V11.16.0 and V11.12.7; highest score is CVSS 8.8.
- WinCC V7.5, V8.0, and V8.1 lack a fix for CVE-2026-59082, CVSS 7.8.
- meta-iot2050 from V01.03.01 has no fix yet for CVE-2026-109830, CVSS 7.3.
- S7 .NET library needs V3.3.62; Femap V2606.0002 and ROS# V2.3.1 are fixed.
- Every listed RUGGEDCOM APE1808 build needs Fortigate NGFW V7.6.9 or later.
Timeline
dated events in the reporting · oldest first- Oct 13, 2026Siemens first published SSA-390352 on the S7 .NET library · CISA Advisories
- Nov 10, 2026Siemens published meta-iot2050 advisory SSA-724261 · CISA Advisories
- Nov 10, 2026Siemens published the Simcenter Femap advisory · CISA Advisories
- Nov 10, 2026Siemens first published ROS# advisory SSA-435267 · CISA Advisories
- Nov 17, 2026CISA republished eight Siemens ProductCERT advisories · CISA Advisories
What each outlet adds
beyond the shared facts- CISA AdvisoriesNTLM relay has no planned fix; encrypt SQL Server traffic
- CISA AdvisoriesMendix MCP flaws; block inbound traffic on port 7782
- CISA AdvisoriesWinCC code execution requires opening a file from an untrusted source
- CISA Advisoriesmeta-iot2050 command injection can run as root
- CISA AdvisoriesRUGGEDCOM issue is a Fortinet newcli crash, CVSS 2.3
Coverage
oldest first · one row per article · UTCRUGGEDCOM APE1808 affected by FortiOS double-free crash flaw
Every listed APE1808 build is affected; a local high-privilege user can crash newcli until Fortigate NGFW V7.6.9.
Siemens SIMATIC NTLM flaw lets on-path attackers hijack sessions
CVE-2026-58114, CVSS 7.5, affects 14 SIMATIC products with no fix available or planned.
Siemens patches Mendix Studio Pro MCP Server exposure and CSRF
Studio Pro 11.15.0 before 11.16.0 and 11.12.6 before 11.12.7 are affected; the top score is CVSS 8.8.
meta-iot2050 firmware tool command injection runs as root
Builds from V01.03.01 onward have no fix yet for CVE-2026-109830, scored CVSS 7.3.
SIMATIC S7 .NET client library leaks passwords and writes files
Path traversal is fixed in V3.3.61; password disclosure in errors needs V3.3.62 or later.
Simcenter Femap out-of-bounds read in X_T parsing fixed
Versions before V2606.0002 can crash or run code when opening a crafted X_T file.
SIMATIC WinCC Graphics Designer executes active content on file open
V7.5, V8.0 and V8.1 have no fix; Siemens says only open files from trusted sources.
Siemens ROS# before 2.3.1 allows code injection via message files
CVE-2026-109097 scores CVSS 8.2 and needs local access plus user interaction; the fix is V2.3.1.
Vulnerabilities in this story
All| CVE | Vulnerability | CVSS | EPSS | Signals | Published |
|---|---|---|---|---|---|
| CVE-2026-106175 | A Double Free vulnerability [CWE-415] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.8, FortiOS 7.4 all versions, FortiOS 7.2 all versions, FortiOS 7.0… | 2.3 | — | ||
| CVE-2026-109097 | Code injection in Siemens ROS# via message definition files | 8.6 | — | ||
| CVE-2026-109830 | Command injection in Siemens meta-iot2050 via config file | 7.0 | — | ||
CVE-2026-112136+1 related CVE | Network-exposed MCP Server in Mendix Studio Pro 11 | 9.2 group max | — | ||
| CVE-2026-58114 | NTLM authentication relay in Siemens SIMATIC products | 7.7 | — | ||
| CVE-2026-59082 | Arbitrary code execution via active content in SIMATIC WinCC | 8.5 | — | ||
| CVE-2026-64629 | A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230), Simcenter Femap (All versions <… | 7.3 | <1% | ||
| CVE-2026-85114 | Path traversal in Siemens .NET SIMATIC S7 Webserver client | 8.7 | — | ||
| CVE-2026-85115 | A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.62) | 6.8 | — |