Siemens Industrial Edge apps hit by Brotli Node2Shell flaw
Original title: Siemens Industrial Edge Management
CVE-2026-111497 is a CVSS 9.8 out-of-bounds write; several configurators have fixes, while others still need mitigations.
CISA republished Siemens guidance on Node2Shell (CVE-2026-111497), a buffer overflow in Google Brotli 1.0.3 through 1.2.0. A remote unauthenticated attacker can use a crafted Brotli stream to corrupt decoder memory, leak data, cause denial of service, or potentially run code. Siemens says setups with no Management Applications need no action, and Hub and Management Cloud already have firewall or WAF protection. Fixes exist for several configurators; others have none yet.
Unconfirmed: Siemens says it is still assessing Node2Shell's impact on Industrial Edge.
- Cloud Connector Configurator is fixed in V1.24.3 or later.
- Data Flow Monitoring is fixed in V3.0.18 or later.
- Common Configurator on IEM and on Edge have no fix yet.
- Industrial Edge Hub was fixed on the cloud service starting October 29.
- Brotli users should move to 1.0.10, 1.1.1, or 1.2.1.
Impact: Memory corruption, data disclosure, denial of service, or code execution
| Product | Affected | Fixed in |
|---|---|---|
| Siemens Cloud Connector Configurator | < V1.24.3 | V1.24.3 or later |
| Siemens Data Flow Monitoring | < V3.0.18 | V3.0.18 or later |
| Siemens Databus Configurator | < V4.0.1 | V4.0.1 or later |
| Siemens DataXess Configurator | < V1.5.7 | V1.5.7 or later |
| Siemens Edge OPC UA Server Configurator | < V2.3.10 | V2.3.10 or later |
| Siemens Flow Creator Configurator | < V1.15.1 | V1.15.1 or later |
| Siemens Common Configurator (CC on IEM) | all | — |
| Siemens Common Configurator on Device (CC on Edge) | all | — |
| Google Brotli | 1.0.3 through 1.2.0 | 1.0.10 or 1.1.1 or 1.2.1 |
- 1.Update listed configurators to the stated fixed versions.
- 2.Uninstall Management Applications and protect IEM with a firewall or WAF until a fix exists.
- 3.Stop Common Configurator on Device until a fix is available.
- CVEs
- CVE-2026-111497
Vulnerabilities mentioned
All| CVE | Vulnerability | CVSS | EPSS | Signals | Published |
|---|---|---|---|---|---|
| CVE-2026-111497 | Buffer overflow in Google Brotli decoder 1.0.3–1.2.0 | 9.2 | 83% | KEVPoC ×25 | KEV |
From the original article
4 min read at cisa.govView CSAF Summary Siemens is currently assessing the impact of Node2Shell (CVE-2026-111497) on Industrial Edge. Please check your Industrial Edge Management (IEM) setup: - No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack, the affected functionality is not used or exposed.
By CISA · cisa.gov
A short excerpt; the article and its images belong to the publisher. Summary, key facts and assessment above are AI-written from the article and can be wrong.