Rockwell Automation ArmorStart LT

AI summary · glm-5.3-flash

CISA flags two flaws (CVE-2026-19471, CVE-2026-19472) in Rockwell Automation ArmorStart LT <=v2.001: stored XSS and web server denial-of-service.

Rockwell Automation reported two issues in the embedded web server of ArmorStart LT v2.001 and earlier. CVE-2026-19471 involves multiple stored cross-site scripting flaws (CVSS 7.3) where unsanitized input is stored server-side and executes in other users' browsers. CVE-2026-19472 is a denial-of-service issue (CVSS 7.5) triggered by a crafted HTTP PUT request that exhausts web server resources. No public exploitation has been reported to CISA.

  • Stored XSS via unsanitized user input persisted on the server
  • DoS via crafted HTTP PUT causes loss of webserver availability
  • Fix by updating beyond v2.001; limit device internet exposure

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2026-19471
Stored XSS in Rockwell Automation ArmorStart LT

CVE-2026-19471 describes multiple stored cross-site scripting (XSS) flaws in Rockwell Automation's ArmorStart LT, caused by user-supplied input that is not properly sanitized before being stored on the device. An attacker can inject malicious scripts into stored fields, and those scripts execute in the browser of any user who later views the affected page in the device's interface. Per the CVSS 4.0 vector, the attack is carried out over the network and requires no privileges or user interaction beyond viewing the stored content, but the rated impact is limited (low impact to confidentiality, integrity, and availability), meaning an attacker could typically run scripts in other users' sessions within the product's interface rather than compromise the broader system. Affected users are organizations running ArmorStart LT distributed motor-control units whose management or web interfaces are accessed by operators and engineers. As of now there is no known public proof of concept, the flaw is not in CISA's KEV catalog, and EPSS estimates only a 0.3% chance of exploitation in the next 30 days.

Do: Monitor the Rockwell Automation security advisory ([email protected]) for the affected version ranges and fixed firmware, and apply the vendor's update when released. In the meantime, restrict access to ArmorStart LT management interfaces to trusted personnel, limit or avoid browser access to the device UI from untrusted endpoints, and ensure the units are segmented from untrusted networks. Because impact is limited to script execution in users' browsers, standard web-session hygiene and network segmentation substantially reduce risk.

6.9<1%
  • Rockwell Automation ArmorStart LT
nichelikely on the order of thousands of installed units across industrial plants, with only a small subset reachable beyond the plant network (estimate; no public…
CVE-2026-19472
Unauthenticated DoS in Rockwell Automation ArmorStart LT embedded web server

Rockwell Automation's ArmorStart LT distributed motor controller contains a denial-of-service flaw in its embedded web server, classified as CWE-770 (allocation of resources without limits). A remote, unauthenticated attacker can trigger it by sending a single specially crafted HTTP PUT request to the device's web interface, per the CVSS 4.0 vector (network attack vector, no privileges or user interaction required). The result is a crash or hang of the web server and loss of the device's web management interface; the CVSS scoring indicates no confidentiality or integrity impact and no impact on downstream systems. Organizations running ArmorStart LT motor controllers, typically in plant-floor OT networks, are affected, especially where the embedded web server is reachable from untrusted networks. No public proof-of-concept or known exploitation exists, the flaw is not in CISA KEV, and EPSS estimates only a 0.3% chance of exploitation in the next 30 days.

Do: Check the Rockwell Automation security advisory for affected and fixed firmware versions (not specified in the available data) and plan a firmware update when releases are identified. Until then, restrict HTTP access to ArmorStart LT web servers to trusted management networks using firewall rules, ACLs, or network segmentation, and avoid exposing the embedded web server directly to the internet. Monitor devices for unexplained web interface outages, which would indicate possible exploitation attempts.

8.7<1%
  • Rockwell Automation ArmorStart LT (distributed motor controller with embedded web server)
nicheunknown; plausibly on the order of tens of thousands of deployed devices worldwide, of which only a small fraction is internet-exposed
Full article561 words · extracted from cisa.gov · click to collapse

View CSAF

Summary

Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page.

The following versions of Rockwell Automation ArmorStart LT are affected:

  • ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472)
CVSS Vendor Equipment Vulnerabilities
v3 7.5 Rockwell Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Allocation of Resources Without Limits or Throttling

Background

  • Critical Infrastructure Sectors: Critical Manufacturing
  • Countries/Areas Deployed: Worldwide
  • Company Headquarters Location: United States

Vulnerabilities

Expand All +

CVE-2026-19471

Multiple stored cross-site scripting security issues exist within ArmorStart LT. Stored XSS occurs when user input is not properly sanitized and is stored on the server, allowing an attacker to inject malicious scripts that will be executed when other users access the affected page.

View CVE Details


Affected Products

Rockwell Automation ArmorStart LT

Vendor:
Rockwell Automation

Product Version:
Rockwell Automation ArmorStart LT: <=v2.001

Product Status:
known_affected

Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N

CVE-2026-19472

A denial-of-service security issue exists within ArmorStart LT. The security issue stems from improper handling of a crafted HTTP PUT request sent to the embedded web server. This can result in a loss of web server availability.

View CVE Details


Affected Products

Rockwell Automation ArmorStart LT

Vendor:
Rockwell Automation

Product Version:
Rockwell Automation ArmorStart LT: <=v2.001

Product Status:
known_affected

Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling


Metrics

CVSS Version Base Score Base Severity Vector String
3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Acknowledgments

  • Rockwell Automation reported these vulnerabilities to CISA.

Legal Notice and Terms of Use

This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


Recommended Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.


Revision History

  • Initial Release Date: 2026-09-03
Date Revision Summary
2026-09-03 1 Initial Republication of Rockwell Automation security advisory.