Experts found critical authentication bypass flaw in Rockwell software

criticalVulnerabilityimportance 60CVE-2021-22681

Vulnerabilities mentionedAll →

CVEVulnerabilityCVSSEPSSFlagsAffectedExposurePublished
CVE-2021-22681
Authentication Bypass in Rockwell Automation Studio 5000 Logix Designer and Logix PLCs

Rockwell Automation's Studio 5000 Logix Designer (versions 21 and later) and RSLogix 5000 (versions 16 through 20) use a shared key to verify that they are communicating with genuine Allen-Bradley Logix controllers, and an unauthenticated remote attacker can bypass this verification mechanism (CWE-522, insufficient protection of credentials). The attack requires only network access to the affected software or controllers - no credentials, no user interaction, and no special conditions (CVSS 3.1: 9.8). By bypassing the verification, an attacker can authenticate to CompactLogix, ControlLogix, DriveLogix, Compact GuardLogix, GuardLogix and SoftLogix controllers and interact with the PLCs, potentially tampering with industrial processes. Any deployment running the affected engineering software versions with the listed Logix controller families is in scope, which spans a very large share of Rockwell's installed base. CISA added this flaw to its Known Exploited Vulnerabilities catalog on 2026-03-05 (ransomware use unknown), and EPSS puts the 30-day exploitation probability at roughly 64%; no public proof-of-concept is known.

Do: Apply mitigations per Rockwell's instructions - the vendor has advised disconnecting internet-facing connections, so remove internet exposure from affected controllers and engineering workstations and segment OT networks. Follow applicable CISA BOD 22-01 guidance, and inventory for Studio 5000 Logix Designer v21+ or RSLogix 5000 v16-20 used with the listed controllers; upgrade per vendor guidance or discontinue use if mitigations are unavailable.

9.864% KEV
  • Rockwell Automation Studio 5000 Logix Designer v21 and later
  • Rockwell Automation RSLogix 5000 v16 through v20
  • Rockwell Automation FactoryTalk Services Platform
  • +6 more
massroughly 1 million or more Logix controller installations (tens of thousands likely internet-exposed)
Full article349 words · extracted from securityaffairs.com · click to collapse

Pierluigi Paganini February 27, 2021

A critical authentication bypass vulnerability could be exploited by remote attackers to Rockwell Automation programmable logic controllers (PLCs).

A critical authentication bypass vulnerability, tracked as CVE-2021-22681, can be exploited by remote attackers to compromise programmable logic controllers (PLCs) manufactured by Rockwell Automation.

The vulnerability was independently reported to Rockwell by researchers at the Soonchunhyang University in South Korea, Claroty, and Kaspersky.

“Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to bypass the verification mechanism and connect with Logix controllers.” reads the advisory published by CISA. “Additionally, this vulnerability could enable an unauthorized third-party tool to alter the controller’s configuration and/or application code.”

The CVE-2021-22681 flaw has received a CVSS score of 10, it affects the following products:

Rockwell software versions:

  • RSLogix 5000: Versions 16 through 20
  • Studio 5000 Logix Designer: Versions 21 and later

Rockwell Logix Controllers:

  • CompactLogix 1768
  • CompactLogix 1769
  • CompactLogix 5370
  • CompactLogix 5380
  • CompactLogix 5480
  • ControlLogix 5550
  • ControlLogix 5560
  • ControlLogix 5570
  • ControlLogix 5580
  • DriveLogix 5560
  • DriveLogix 5730
  • DriveLogix 1794-L34
  • Compact GuardLogix 5370
  • Compact GuardLogix 5380
  • GuardLogix 5570
  • GuardLogix 5580
  • SoftLogix 5800

The issue resides in the Logix Designer software that uses a poorly protected private cryptographic key to verify communications with controllers.

“This key is not sufficiently protected, allowing a remote, unauthenticated attacker to bypass the verification mechanism and connect to the controller by mimicking an engineering workstation.” reads the post published by Claroty. “An attacker who is able to extract the secret key would be able to authenticate to any Rockwell Logix controller.”

The secret keys are used to digitally sign all communication with the Rockwell PLCs, then PLCs verify the signature and authenticate the company engineering software. An attacker that obtained the key impersonate the engineering software and control the PLC.

Claroty privately reported the vulnerability to Rockwell in 2019.

Rockwell provided a list of risk mitigation and recommended user actions for its projects.