ZeroHour

Search: “VPN”

18 stories

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 13d agoAdvisoryCVE-2026-75925

Check Point security advisory (AV26-902)

Canada's Cyber Centre issued advisory AV26-902 warning of two Check Point RCE flaws, including VPN authentication bypass CVE-2026-85102.

The Canadian Centre for Cyber Security released advisory AV26-902 on September 9, 2026, covering vulnerabilities in Check Point Security Gateway, Spark Firewall with Site-to-Site or Remote Access VPN, and Security Management Server across multiple versions. CVE-2026-85102 is an authentication bypass and remote code execution flaw in Remote Access and Site-to-Site VPN, while CVE-2026-85103 is an ASN.1 decoding heap overflow enabling remote code execution. Administrators are urged to review the linked advisories and apply updates as they become available.

AL26-019 - Vulnerabilities impacting Citrix NetScaler ADC and NetScaler Gateway - CVE-2026-19490 and CVE-2026-19489

Canadian Cyber Centre alerts on Citrix NetScaler ADC/Gateway flaws CVE-2026-19490 (authentication bypass) and CVE-2026-19489 (buffer overflow), urging emergency patching.

The Canadian Centre for Cyber Security issued alert AL26-019 covering two Citrix NetScaler vulnerabilities disclosed in a vendor advisory on August 19, 2026. CVE-2026-19490 (CWE-288) allows a remote unauthenticated attacker to bypass authentication on appliances configured as a Gateway for SSL VPN, ICA Proxy, CVPN, RDP Proxy, or as an AAA virtual server. CVE-2026-19489 (CWE-120) is a classic buffer overflow that may cause memory overflow, unpredictable behavior, or denial-of-service conditions. Affected appliances are vulnerable when configured as a SAML IdP; fixed versions include 14.1-73.32, 13.1-63.21, and 13.1-37.277 for FIPS.

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

CISA Advisories · 1d agoAdvisoryCVE-2026-80465

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-4827

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

CISA details CVE-2026-61884 (CVSS 9.8) in Tycon Systems TPDIN-Monitor-WEB2: unauthenticated access to power relays when credentials are unset; fixed in 2.4.5.

CISA updated its advisory for Tycon Systems TPDIN-Monitor-WEB2 firmware below 2.4.5, covering two vulnerabilities. CVE-2026-61884 (CVSS 9.8, CWE-306) lets any network attacker reach full device controls, including power relay management and reboots, on units left without configured HTTP credentials. CVE-2026-55985 exposes stored system credentials in cleartext to authenticated dashboard users, enabling compromise of other local systems. No public exploitation has been reported to CISA.

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 13d agoAdvisoryCVE-2026-78012

AI-fueled attacks pose ‘active threat’ to water, other sectors, U.S. agencies warn

NSA, CISA, FBI, DOE and EPA warn hackers are using AI-generated scripts to actively attack Siemens S7 PLCs across critical-infrastructure sectors.

A joint cybersecurity advisory from the NSA, CISA, FBI, Department of Energy and EPA warns of an active threat campaign targeting water, food, energy, chemical, manufacturing and commercial facilities via Siemens S7 Series programmable logic controllers. The actors use internet scanning to find exposed or poorly protected PLCs, then deploy AI-generated exploitation scripts disguised as legitimate monitoring tools, an OT first that dramatically lowers the expertise required for ICS attacks. Siemens says no new S7 vulnerabilities are involved, only exploitation of misconfigurations, and it is coordinating with CISA's ProductCERT. The warning follows a joint FBI-EPA advisory confirming attacks at water and wastewater utilities in at least 12 states since July 27.

CyberScoop · 27d agoAdvisory in the wild1