ZeroHour

Search: “energy”

66 stories

AI-fueled attacks pose ‘active threat’ to water, other sectors, U.S. agencies warn

NSA, CISA, FBI, DOE and EPA warn hackers are using AI-generated scripts to actively attack Siemens S7 PLCs across critical-infrastructure sectors.

A joint cybersecurity advisory from the NSA, CISA, FBI, Department of Energy and EPA warns of an active threat campaign targeting water, food, energy, chemical, manufacturing and commercial facilities via Siemens S7 Series programmable logic controllers. The actors use internet scanning to find exposed or poorly protected PLCs, then deploy AI-generated exploitation scripts disguised as legitimate monitoring tools, an OT first that dramatically lowers the expertise required for ICS attacks. Siemens says no new S7 vulnerabilities are involved, only exploitation of misconfigurations, and it is coordinating with CISA's ProductCERT. The warning follows a joint FBI-EPA advisory confirming attacks at water and wastewater utilities in at least 12 states since July 27.

CyberScoop · 26d agoAdvisory in the wild1

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

US agencies warn of AI-powered attacks on Siemens industrial controllers

NSA, CISA, FBI, DOE, and EPA warn threat actors use AI-assisted scripts and snap7 libraries to access internet-exposed Siemens S7 PLCs in critical infrastructure sectors.

NSA, CISA, FBI, DOE, and EPA issued a joint advisory warning that threat actors combine open-source snap7.dll/python-snap7 libraries with AI-generated scripts to gain read/write access to Siemens S7-200 through S7-1500 PLCs over the S7comm protocol. Actors use Censys and ZoomEye to find internet-exposed devices and abuse default or weak credentials, with activity assessed as persistent reconnaissance and positioning for future write operations. Agencies urge device inventory, patching, removing PLCs from the internet, and hardening; the pattern resembles Iran-linked CyberAv3ngers targeting of Rockwell, Schneider, and Siemens PLCs.

Help Net Security · 26d agoAdvisory in the wild

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

CISA updated ICSA-26-169-07: CVE-2026-4827 (CVSS 8.3) insufficient entropy enables session hijacking across dozens of Schneider Electric grid products; fixes available.

CISA republished advisory ICSA-26-169-07 (Update A) for CVE-2026-4827, CWE-331 insufficient entropy in session management, scored CVSS 8.3. Affected lines include Easergy MiCOM relays and C5, EcoStruxure Power Automation (EPAS-GTW, EPAS-UI, iPMFLS), EcoStruxure Power Operation, PowerLogic P5/P7/T300/T500, and Saitel DP/T150 RTUs, with dozens of fixed versions listed. Successful exploitation could enable session hijacking and unauthorized operations on systems in energy, chemical, critical manufacturing, and water sectors. Fixes are available; no exploitation is reported.

CISA Advisories · 12d agoAdvisoryCVE-2026-4827

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

CISA Urges Service Providers to Provide Transparent Updates During Major IT and OT Outages

CISA and FBI issued guidance urging service providers to deliver timely, transparent communications during major IT and OT outages.

CISA, with the FBI and international partners, released 'Communicating Under Pressure: Best Practices for Service Providers', urging providers to prepare crisis-communication procedures, provide timely status updates during IT/OT outages, and maintain out-of-band communication channels. The guidance warns that disruptions to telecom, cloud, energy, and water services can cascade across critical infrastructure. It aligns with CISA's CI Fortify initiative supporting IT/OT isolation and recovery.

GBHackers · 4d agoAdvisory

ST Engineering iDirect iQ-Series Terminals (Update A)

CISA advisory details four flaws in ST Engineering iDirect iQ-Series VSAT terminals <=4.5.2.1, enabling device data theft, CSRF-driven reboots, and local privilege escalation.

CISA's Update A to ICSA-26-183-01 covers ST Engineering iDirect iQ-Series, 3315-Series and 9-Series terminals at firmware <=4.5.2.1, deployed across communications, defense, energy and transportation. CVE-2026-38059 exposes unauthenticated /api/identity and /api/ endpoints leaking serial number, DID, TPK, MAC address and firmware version, potentially enabling terminal impersonation; CVE-2026-38057 is a CSRF flaw letting an attacker force terminal reboots and satellite link loss via /api/reboot. CVE-2026-38056 enables local privilege escalation using the factory-configured technician account (CVSS 3.1 8.8, CVSS 4.0 9.4), and CVE-2026-38058 exposes crackable MD5-crypt root password hashes. All four flaws were reported to CISA by Ahmed Alqahtani of Aramco.

Windows 11 cumulative updates KB5124008 & KB5122880 released

Microsoft shipped mandatory September 2026 Patch Tuesday cumulative updates KB5124008 and KB5122880 for Windows 11, fixing vulnerabilities and adding features.

Microsoft released Windows 11 KB5124008 (versions 25H2/24H2) and KB5122880 (23H2) cumulative updates containing the September 2026 Patch Tuesday security patches, described as covering 1,000 vulnerabilities discovered in previous months. The updates are mandatory and add features including movable and resizable taskbars, Start menu customization, a Windows Search option to hide Bing and Store web suggestions, and Administrator Protection, a just-in-time admin privilege feature that is off by default and configurable via Intune OMA-URI or Group Policy.

BleepingComputer · 7d agoAdvisory

CISA tells operators to harden Siemens S7 PLCs. Here’s how to do it without disrupting production

CISA, NSA, FBI and other agencies warn of active targeting of internet-exposed Siemens S7 PLCs and urge patching, exposure removal and hardening.

Joint advisory AA26-231A from the NSA, CISA, FBI, Department of Energy and EPA warns that actors are actively targeting Siemens S7 PLCs using internet scanning, AI-assisted scripts and libraries such as Snap7 and python-snap7 over S7comm on TCP port 102. The advisory covers S7-200 through S7-1500 series controllers and recommends patching, removing internet exposure, access controls, monitoring and disabling unneeded services. Siemens states no new S7 vulnerabilities are involved, only misconfigurations addressed in existing ProductCERT guidance SSB-104599. The article details how to apply each measure without breaking production dependencies such as remote I/O, HMI links and diagnostics.

CSO Online · 7d agoAdvisory in the wild

Rockwell Automation ControlFLASH

CISA advisory for CVE-2026-12663 (CVSS 7.3) in Rockwell Automation ControlFLASH <=V15.07: world-writable install directory enables local code execution.

Rockwell Automation reported CVE-2026-12663 in ControlFLASH V15.07 and earlier, where the installer grants write permissions on the installation directory to the Everyone group. An attacker could plant malicious code there and execute it at the logged-in user's privilege level. The issue is local only and not remotely exploitable; no public exploitation has been reported to CISA.

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

CISA warns CVE-2026-77477 (CVSS 4.6) lets local attackers hijack a privileged console during OPC UA LDS installation below version 1.04.420.

CISA published ICSA-26-246-01 for CVE-2026-77477, CWE-250 execution with unnecessary privileges in OPC Foundation UA-LDS-Installers below 1.04.420. An attacker able to launch the installer with elevated privileges and access the keyboard and display can intercept a high-privilege console window during installation and run arbitrary commands. CVSS 3.1 score is 4.6, the issue is not remotely exploitable, and no public exploitation has been reported. Lukas Schumaker of Rockwell Automation reported the flaw to OPC Foundation.

CISA Advisories · 12d agoAdvisoryCVE-2026-77477

Pyramid Solutions NetStaX EtherNet/IP Stack

CISA flags critical CVE-2026-78012 (CVSS 9.8) stack buffer overflow in Pyramid Solutions NetStaX EtherNet/IP stacks below v5.6.1, risking crashes or remote attack vectors.

CISA republished Pyramid Solutions' advisory for CVE-2026-78012, a CWE-121 stack-based buffer overflow in the NetStaX EtherNet/IP stack versions prior to 5.6.1, scored CVSS 9.8. Large Class 3 explicit-message requests can exceed the application-side receive buffer without generating a CIP error, potentially causing memory corruption, device crashes, or a silent remote attack vector. All eight adapter and scanner DLL/development kit variants, including CIP Security editions, are affected across critical manufacturing, energy, water, and chemical sectors. No public exploitation has been reported.

CISA Advisories · 12d agoAdvisoryCVE-2026-78012

Tycon Systems TPDIN-Monitor-WEB3

CISA reports three flaws (hard-coded credentials, CSRF, missing authorization) in Tycon TPDIN-Monitor-WEB3 <=2.2.9 enabling MitM, credential theft, or device resets.

CISA published ICSA-26-246-08 for Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior, covering CVE-2026-77847 (use of hard-coded credentials, CWE-798), CVE-2026-82712 (CSRF, CWE-352), and CVE-2026-82684 (missing authorization, CWE-862). Exploitation could enable man-in-the-middle attacks, factory resets, credential wiping, or extraction of system credentials, configurations, and flash contents; the CSRF issue scores CVSS 8.8. No public exploitation has been reported; CISA recommends isolating devices from business networks.

IXON VPN Client

CISA warns CVE-2026-75925 (CVSS 9.6) in IXON VPN Client <1.4.7 lets attackers inject config directives for root/SYSTEM remote code execution.

IXON's CRLF injection flaw (CVE-2026-75925, CWE-93) in VPN Client before 1.4.7 lets the unauthenticated local configuration service inject additional directives into a file consumed by a privileged subprocess. Injected configuration persists across client and OS restarts, enabling code execution as root or SYSTEM while the VPN connection keeps functioning normally. Deployments span energy, manufacturing, water, and IT sectors; no public exploitation has been reported to CISA.

CISA Advisories · 12d agoAdvisoryCVE-2026-75925

Inductive Automation Ignition

CISA reports a permissions flaw (CVE-2026-77393, CVSS 8.8) in Inductive Automation Ignition <=8.1.53 letting authenticated users create projects; fixed in 8.1.54.

CISA republished Inductive Automation's advisory for CVE-2026-77393, an incorrect default permissions issue (CWE-276) in Ignition 8.1.53 and earlier. The Gateway "Create Project Role(s)" setting shipped blank, allowing any authenticated user who can execute gateway scripts to create projects. Ignition 8.1.54 restricts project creation to Designer sessions and the 8.3 series is unaffected. CISA notes no known public exploitation of this vulnerability.

CISA Advisories · 12d agoAdvisoryCVE-2026-77393

Water sector passes, government sector fails attempts to spot and halt simulated CISA attack

CISA red teamers compromised both a government and a water organization; water defenders detected and contained the simulated attack, government defenders did not.

CISA's red team gained initial access, elevated domain privileges, and lateral movement into sensitive business systems and cloud resources at an unnamed government organization, whose SOC ignored low- and medium-severity EDR alerts buried under thousands of false positives. A water organization's SOC quarantined phishing-compromised workstations within 2, 10, and 20 minutes, and later detected and isolated intrusions reaching the OT DMZ bastion host. Both organizations underestimated cloud risk, lacked Microsoft Conditional Access for workload identities, and had no process to revoke compromised access and refresh tokens. This is one of CISA's rare public red-team reports since 2023.

CyberScoop · 21d agoAdvisory1