ZeroHour

Source: CISA Advisories

9 stories in the last 24h

Protecting Tokens and Assertions from Forgery, Theft, and Misuse: Implementation Recommendations for Agencies and Cloud Service Providers

NIST and CISA publish final interagency report with implementation guidance for protecting tokens and assertions from forgery and misuse.

CISA released a final NIST/CISA interagency report guiding federal agencies and cloud service providers on protecting identity assertions, access tokens, and cryptographic mechanisms underlying modern authentication and authorization. It addresses forgery, theft, and misuse of signed tokens that adversaries use for lateral movement and data access in hybrid and multi-cloud, SSO, federation, and API-based environments. The final version updates token validation, secrets management, and detection-at-scale guidance gathered via the Joint Cyber Defense Collaborative, and supports Executive Order 14306 and Secure by Design principles.

CISA Advisories · 10h agoAdvisory

Digital Watchdog VMAX DVR and NVR Product Lineups

CISA advisory details six flaws, aggregate CVSS 9.6, giving attackers full control of Digital Watchdog VMAX DVR/NVR surveillance devices.

CISA advisory ICSA-26-258-01 discloses six vulnerabilities affecting all versions of Digital Watchdog VMAX A1 G4 DVRs, VMAX IP G4 NVRs, VMAX A1 PLUS, VA1G4, and VG4 recorders, with aggregate CVSS v3 of 9.6. Flaws include an authentication bypass leaking plaintext admin credentials (CVE-2026-68953), hard-coded credentials enabling root FTP access (CVE-2026-66890, CVE-2026-68950), root command execution (CVE-2026-68070), missing authorization on state-changing CGIs (CVE-2026-66887), and predictable session tokens (CVE-2026-66372). Successful exploitation grants full administrative control, live and recorded surveillance access, and a network pivot point. Products are deployed worldwide across commercial facilities, government, healthcare, and transportation sectors.

Siemens Teamcenter

Reflected XSS in Siemens Teamcenter /auth/ redirect flow lets unauthenticated attackers inject JavaScript into authenticated sessions (CVE-2026-58113).

CISA republished Siemens advisory SSA-157465 for CVE-2026-58113, a reflected cross-site scripting flaw (CVSS 6.1) in the /auth/ authentication redirect flow of Siemens Teamcenter V2412, V2506, V2512, and V2606. An unauthenticated attacker can craft a URL that injects arbitrary JavaScript into an authenticated user's browser, enabling data theft or actions within the victim's Teamcenter session. Fixed versions are available for all affected releases; Enzo Alvarez of Bishop Fox reported the vulnerability.

Siemens Mendix SAML

Siemens Mendix SAML module fails signature validation, allowing unauthenticated account hijacking in specific SSO configurations (CVE-2026-80465).

CISA republished Siemens advisory SSA-887643 for CVE-2026-80465 (CVSS 8.7) in the Mendix SAML module, affecting Mendix 10/11-compatible versions before 4.2.3 and Mendix 9.24-compatible versions before 3.6.27. The module improperly validates SAML response signatures (CWE-347), letting unauthenticated remote attackers hijack an account in specific SSO configurations. Mendix has released fixed versions and recommends updating.

Siemens Reyrolle 7SR5

CISA advisory covers 14 vulnerabilities, CVSS 9.8, in Siemens Reyrolle 7SR5 energy-sector protection relays before V2.70.

CISA advisory ICSA-26-258-05 covers 14 vulnerabilities in Siemens Reyrolle 7SR5 protection relays before V2.70, used in the energy sector worldwide, with aggregate CVSS v3 of 9.8. Flaws include Cesanta Mongoose web server issues (CVE-2024-42384 through CVE-2024-42392) and new bugs such as web-interface session-ID exposure enabling authentication bypass (CVE-2026-62645, CVSS 9.8), predictable session tokens (CVE-2026-62646, CVE-2026-62647), and pre-auth out-of-bounds writes (CVE-2026-62648). Siemens has released V2.70 and recommends updating to the latest version.

CareCam CM2507

CISA advisory: seven flaws in CareCam CM2507 IP cameras enable unauthenticated live video access, privileged ONVIF control, credential recovery, and code execution.

CISA advisory ICSA-26-258-08 discloses seven vulnerabilities in CareCam HMT.CM2507 IP cameras running firmware v251211.1507. Issues include missing authentication for network video streaming (CVE-2026-88259, CVSS 3.1 7.5), an empty password on a privileged ONVIF account (CVE-2026-84398), weak legacy hashing of the root password (CVE-2026-85497, CVSS 4.0 9.3 critical), and cleartext storage of Wi-Fi credentials (CVE-2026-81321). Physical-access flaws allow arbitrary code execution from scripts on removable media (CVE-2026-81305) and unauthenticated bootloader access (CVE-2026-85478). The cameras are deployed worldwide in commercial facilities.

Wärtsilä FOS-Onboard

CISA advisory: two hardcoded cryptographic key flaws in Wärtsilä FOS-Onboard 5.07.0923.01 (CVSS 9.0/9.1) could allow unauthorized updates, code execution, and credential theft.

CISA advisory ICSA-26-258-02 discloses CVE-2026-78225 (CVSS 3.1 9.0 critical), a hardcoded cryptographic server key in the deployer-ng Update Controller of Wärtsilä FOS-Onboard 5.07.0923.01. CVE-2026-81855 (CVSS 3.1 9.1 critical) is a hardcoded client authentication key in the robot testing framework component. Successful exploitation could let an attacker deliver unauthorized updates, execute code, or extract credentials to impersonate a privileged client. The product is deployed worldwide in transportation systems critical infrastructure; Cydome Security reported the flaws and CISA states no known public exploitation exists.

mySCADA myPRO Manager

CISA advisory reveals unauthenticated privileged API access and arbitrary SMS sending in mySCADA myPRO Manager <=2.1, CVSS 9.8.

CISA advisory ICSA-26-258-03 discloses two vulnerabilities in mySCADA myPRO Manager <=2.1 with aggregate CVSS v3 of 9.8. CVE-2026-73807 (CVSS 9.8) lets unauthenticated network attackers access privileged management functions via the command API, while CVE-2026-82567 exposes an unauthenticated HTTP endpoint that sends arbitrary SMS messages through a connected GSM modem. Deployments span critical manufacturing, energy, food and agriculture, transportation, and water and wastewater sectors. CISA states no known public exploitation has been reported at this time.

Schneider Electric SCADAPack x70 Products

CISA advisory: Schneider Electric SCADAPack x70 RTUs contain CVE-2026-81861, an insufficiently protected credentials flaw allowing unauthorized access to RTU configuration.

CISA advisory ICSA-26-258-04 discloses CVE-2026-81861 affecting all versions of Schneider Electric SCADAPack 47x, 47xi, 47xd, 470R, 57x, 3xx, and 32 remote terminal units. The CWE-522 insufficiently protected credentials vulnerability could expose authentication information and permit unauthorized access to RTU configuration through the Secure Lock functionality. The flaw carries a CVSS v3.1 base score of 6.5 (medium), and the products are deployed worldwide in critical manufacturing and energy sectors. Abhinav Agarwal reported the vulnerability to CISA.